3. If you are using a dial-up modem with the Voice Interface, disable auto-answer. With the recommended
U.S. Robotics modem, this is accomplished by setting DIP switch number 5 to the DOWN position. With
auto-answer disabled, the Voice Interface will answer voice calls in Voice Mode and when data calls are
received, the dialing modem sends the code to enter data mode (see page 18).
Note: If you are not using a dial-up modem with the Voice Interface, you can plug a telephone set into the
Set/Modem jack. This allows a single wall jack to accommodate your Voice Interface and a telephone.
DIALING IN & DISCONNECTING
Dialing In
When you dial the telephone number for the Voice Interface, the unit answers with the programmed greeting
message after the number of rings you specified during unit configuration (see page 47). After the greeting,
enter an access code, which is also set up in unit configuration. The default password is the telephone keypad
equivalent of PASSWORD (72779673). Press # after entering the access code.
Note: The Voice Interface allows three attempts to enter the password. If you make a mistake on the third attempt,
the unit will disconnect.
If there are alarms at your site, the Voice Interface will identify the I/O units on which they are located and
immediately connect to the first I/O unit with an alarm. If there are no alarms, the unit will connect to Unit 0
and report, “No alarms pending.”
Disconnecting
You can end your call at any time by entering 9
99
99
9. The Voice Interface will play the goodbye message and
disconnect.
The Voice Interface will also disconnect if it is expecting a response from the user and none is received within an
allotted timeout period. The Inactivity Timeout is set up under the Voice Setup tab in Unit Configuration (see
page 47).
SELECTING AN I/O UNIT
(GSC3000 ONLY)
While in a voice session, you are always connected to a particular I/O unit, and the commands, status reports,
captures, etc. all refer to that I/O unit.
To switch from one I/O unit to the next, enter 9, followed by the two-digit unit number for the I/O you would
like to connect to. Valid entries are 900-915.
E
Exxa
am
mp
plle
e
If you enter an I/O unit number that has not been assigned to any unit, or a number higher than 15, the unit will
respond, “I/O unit does not exist.”
GSC3000 & VRC2500 INSTALLATION & OPERATION MANUAL
CHAPTER 11: VOICE INTERFACE OPERATION
114
IIn
np
pu
utt::
904
R
Re
essp
po
on
nsse
e:: Connecting to Unit 4 [BEEP] … [BEEP]
Connection to Unit 4 Complete.
Содержание GSC3000
Страница 8: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL viii ...
Страница 22: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 14 ...
Страница 32: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 24 ...
Страница 40: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 32 ...
Страница 52: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 44 ...
Страница 61: ...CHAPTER 6 MODEM SITE EQUIPMENT CONNECTIONS 53 CUSTOMER SUPPORT 978 486 3711 support burk com www burk com ...
Страница 68: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 60 ...
Страница 120: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 112 ...
Страница 128: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 120 ...
Страница 132: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 124 ...
Страница 140: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 132 ...
Страница 144: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 136 ...