niitt.. Enter the unit of measurement (i.e. volts, watts, amps, etc.) used by this metering channel (up to four
characters). The Voice Interface is able to recognize the following abbreviations and speak the full unit name:
%
%
Percent
A
AM
MP
PS
S Amps
D
DB
B
Decibels
D
DE
EG
G
Degrees
G
GA
ALL
Gallons
K
KV
V
Kilovolts
K
KW
W
Kilowatts
LLB
BS
S
Pounds
M
MA
A
Milliamps
M
MIIN
N
Minutes
M
MV
V
Millivolts
P
PO
OW
WR
R Power
S
SE
EC
C
Seconds
V
VLLT
TS
S
Volts
W
WA
AT
TT
T Watts
T
Ty
yp
pe
e.. Click in the Type field and use the drop down menu to select the type of metering this channel uses:
After you set up names, units and input types for your
channels, click the + sign to the left of the channel
number to set up limits and alarms, and to associate
events with those channel alarms.
LLiim
miittss.. You can set up four separate limit parameters for each channel (two lower limits and two upper limits),
allowing different alarms to be issued and actions to be taken depending on which limit has been exceeded.
Enter the limits in ascending order, according to the metering value:
S
Se
ecco
on
nd
d LLo
ow
we
err
The lowest limit value. Any meter reading at or below this value will cause the
alarm/action associated with the Second Lower limit.
FFiirrsstt LLo
ow
we
err
The higher of the two lower limits. When the monitored value reaches the First
Lower limit, the associated alarm/action is initiated until the value reaches the
Second Lower limit. If only one lower limit is needed, use the second lower limit, as
the system responds only to the second limit when both are exceeded. Leave the
first lower limit set to 0.
GSC3000 & VRC2500 INSTALLATION & OPERATION MANUAL
CHAPTER 4: I/O UNIT CONFIGURATION
36
0
0 tto
o 1
10
0
Allows an analog input of 0VDC up to +10VDC with the same ratio assigned for all
values in that range.
--5
5 tto
o +
+5
5
Allows an analog input of –5VDC to +5VDC with the same ratio assigned for all
values in that range.
LLiin
ne
ea
arr tto
o P
Po
ow
we
err
Allows an analog input to this channel of 0VDC up to +10VDC with an exponential
ratio calculated for all values in that range.
IIn
nd
diirre
ecctt P
Po
ow
we
err
Disables direct input to the channel. The displayed value is based on the input
values of the previous two channels. For example, the value of Channel 2 and the
value of Channel 3 are multiplied to give the value for Channel 4.
Содержание GSC3000
Страница 8: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL viii ...
Страница 22: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 14 ...
Страница 32: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 24 ...
Страница 40: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 32 ...
Страница 52: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 44 ...
Страница 61: ...CHAPTER 6 MODEM SITE EQUIPMENT CONNECTIONS 53 CUSTOMER SUPPORT 978 486 3711 support burk com www burk com ...
Страница 68: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 60 ...
Страница 120: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 112 ...
Страница 128: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 120 ...
Страница 132: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 124 ...
Страница 140: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 132 ...
Страница 144: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 136 ...