install - concepts - PixMaster - switcher - CG - clips - controls - team - appendix
Broadcast Pix
V3.0
4.11.4 Optional Remote Panels
As an option you may remotely control any Switcher output with Remote Panels. The
Remote Panels are 1RU frames that connect directly to the Mica Switcher and to the
Mica Server to provide Aux bus selection, as well as act as a Macro Player to trigger
premade switcher effects. They are ideal in replay applications where each replay
station needs control of an output to select an input or for an engineering station to
monitor color and shading adjustments of multiple inputs.
Up to 40 Remote panels may be connected to the Mica System through a 100BASE-T
TCP/IP connection. Each panel can be configured with different user modes, which can
restrict or allow access of any input or output.
4.11.5 Remote Panel Wiring
The Remote Panel, Mica Server and Control Panel all must be on
the same network using a Network Switch using standard straight-through Cat5e cables.
The Remote Panels fit into a standard 19” rack, with the integrated rack ears, which are
not removable. Wire the Remote Panel(s) as described below:
1.
Connect the Remote Panel(s) to a Network Switch using the
To Switcher
connector. (Note the Network Switch is not provided by Broadcast Pix)
2.
Connect the Mica Server to the same Network Switch using the
motherboard
NIC
connector.
3.
Connect the Control Panel to the same Network Switch using either one of the
Network
connector.
4.11.4
Network Switch
Remote Panel
1 ME Control Panel