Fig. 7-14:
Programming the MZA messages
Network 1 generates the E-stop message 401 if iEStopOK = FALSE. If iFuse‐
Coolant = False, an NC stop message 601 is generated. This message re‐
mains active until the Reset key is actuated. Network 3 generates an NC stop
M30 message if the iOilFilterJam input is set to TRUE for at least 10 s.
An MZA message can always be programmed at any point in the PLC user
program. We recommend that you program an MZA message in the "prDiag"
program because this considerably facilitates finding the message.
7.4.5
Managing the message texts
Message texts are saved in ASCII files in the file system of the CNC. One file
is created for each language. The file name is mzatexte.xxx, with xxx stand‐
ing for the language of the message file. The file storage location is /usrfep.
Fig. 7-15:
MZA file names
A total of 2048 messages can be defined. Each message is assigned a serial
number from 1 to 2048. The list of messages can contain gaps.
The messages are distinguished as follows:
●
Machine errors have an ID of E
●
Machine warnings have an ID of W
●
Machine notes have an ID of M
Bosch Rexroth AG
DOK-MTXMIC-EASY*******-CO06-EN-P
84/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
PLC commissioning