5.4.8
VAC06.1
MOP keys
Electrical data
Override switch
Protection type
Connection and supply
USB
IP20
-
none
none
Inputs/outputs
24E/16A
Con. for ext. handwheel
available
Fig. 5-14:
Technical data of the VAC06.1 I/O box
5.5
Selecting and connecting the hardware
5.5.1
Configuration instructions
Power connection
The HCQ02 or HCT02 is directly connected to the external power supply via
terminal X3. The allowed line voltage range is 200..500 V ULN. The allowed
line frequency range is 50..60 Hz. Any other values specified below refer to
the typical case of connection to a power supply network of 3 AC 400 V, 50
Hz.
Bosch Rexroth AG
DOK-MTXMIC-EASY*******-CO06-EN-P
44/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Selecting and connecting the hardware