-F1
Line fuse
HNL
Line reactor
-K1
Line contactor
Fig. 5-28:
Recommended arrangement of components in the control cabinet
●
Run cables and lines for control signals and power signals in
separate cable ducts.
●
Use shielded Rexroth cables and lines for connecting motors
and encoders.
●
Make absolutely sure that you adhere to the grounding con‐
cept and specifically that you use a low-resistance protective
conductor connection.
●
It is only allowed to install the HC*02 in a vertical position
(G1).
Hot parts with temperatures higher than
105 °C may result in material damage!
DANGER
●
Keep the specified minimum distances from other components.
●
Materials present above the devices may only be materials which are in‐
combustible and insensitive to the high temperatures that occur.
Bosch Rexroth AG
DOK-MTXMIC-EASY*******-CO06-EN-P
58/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Selecting and connecting the hardware