11
Data backup and serial commissioning
11.1
Data backup
11.1.1
General information
After the machine has been put into commission, the project data should be
backed up. The data backup can be made both in IndraWorks Engineering
and directly on the machine control panel.
Data backup of individual files
We recommend that you make a data backup with IndraWorks Engineering in
the commissioning phase and if you wish to store individual parts of the proj‐
ect. In addition to making a complete backup of the project data, you can also
store the drive parameters, the CNC parameters and the PLC program in
separate files and reload them separately as well.
Complete backup
Data backup on the machine control panel is made via the USB port and
stores the complete user data. This is particularly reasonable after commis‐
sioning has been completed and to back up the data at the end customer's.
In this case, the data backup procedure is much easier "Single Button Back‐
up" than with IndraWorks Engineering.
11.1.2
Data backup with IndraWorks Engineering
Proceed as follows to back up the project data:
1. In the main menu, select Project – Archive….
2. Define a name for the archive and, if necessary, a comment and a pass‐
word (continue with "Next >>").
3. Select a storage location for the archive by activating the "Store Archive
on File System" checkbox. Deactivate the "Store Archive on FTP Serv‐
er" checkbox.
4. 4. In the next step, define the data to be filed to the archive in addition to
the PLC program. This requires that you click on the
"IndraMotion_MTX_micro" node in the left-hand window.
The following data can be selected from the right-hand window:
●
Control data – to back up CNC parameters and programs
●
Extended data – to back up additional files
●
Drive data – to back up drive parameters
5. Confirm your selection, and the screen will display a summary of the da‐
ta to be backed up. Click on <Finish> to start archiving. After archiving
has been completed, the screen will again show a summary.
chapter "Restoring data from the USB flash drive/CF card" on
contains a detailed description of how to restore an ar‐
chive.
DOK-MTXMIC-EASY*******-CO06-EN-P
Bosch Rexroth AG
147/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Data backup and serial commissioning