DiBos/DiBos Micro
Default Configuration | en
91
Bosch Sicherheitssysteme GmbH
Installation Guide
F.01U.033.308 | V7 | 2009.09
And
All selected inputs and cameras with motion detection must
trigger in order to start the job.
Or
Only one input or one camera with motion detection must
trigger in order to start the job.
3
Day I Night I Weekend
...
Select the time profile. The job is assigned to this time
profile.
Note:
Only the time profiles configured under
Time periods
are
displayed.
Note:
With the
Copy settings to other time periods...
button, it is
possible to quickly copy jobs to other time periods.
4
Alarm recording list
The inputs or cameras selected under
Trigger
trigger an
alarm recording for locally connected cameras.
Edit...
Click the button. A dialog box opens. Select the cameras for
which alarm recording should take place.
Protect alarm
recordings
Activate the check box. The alarm recordings are protected
against overwriting (including pre-alarm images).
Note:
Protected data will only be automatically deleted after a
specified number of days if the
Delete old video
and
Delete
protected data
options are activated under
Recording
settings
. It is also possible to manually delete data via the
user interface.
5
Relay control
Specify the relay that is to be controlled.
Activate
Activates the relay to be controlled.
Relay:
Select the relay to be controlled.
Action:
Select the relay behavior.
Relay behavior:
–
Start of event
: At the start of an event the relay switches
for one second.
–
End of event
: At the end of an event the relay switches
for one second.
–
Follow event
: The relay switches at the beginning of the
event, maintains this status during the event and returns
to its original status at the end of the event.
–
Follow recording
: The relay switches at the start of the
event and only returns to its original status after the end
of alarm recording (including the post-alarm time).