138
en | Connections
DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09
Installation Guide
Bosch Sicherheitssysteme GmbH
Time lag: Select
0
(hours) and
Daylight saving time
License: Enter serial number and activation code (please note these entries are case
sensitive) and confirm with
OK
.
–
Click
Save
.
–
Click
Yes
in the information window to start the
Time Synchronization
service.
Note:
A timer appears in the Windows XP task bar (at the bottom edge of the screen). This
confirms that the
Time Synchronization
program has started. The color of the clock
depends on the receiver status.
Yellow: Program starting (takes up to three minutes!)
Red: No synchronization or installation error
Green: Synchronization of system clock with receiver is OK.
6.
Exit the
NeoClock Time Server
service as follows:
–
Select
Start
->
Control Panel
->
Administrative Tools
->
Services
.
–
Double-click
NeoClock Time Server
and click
Exit
under
Service Status
(
General
tab) to exit it.
–
Deactivate the service by selecting
Deactivated
as the
Start type
.
–
Confirm with
OK
and close the
Services
dialog box and the Control Panel.
7.
Reboot the PC.
8.
The
NeoClock Time Server
program must not be configured; instead, TARDIS should be
used. (Program used to synchronize video systems in a network; can be requested from
the video system manufacturer's video product service).
9.
To position the clock, use the NeoClock XP operating manual (available on the CD as a
PDF file).