44
en | Default Configuration
DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09
Installation Guide
Bosch Sicherheitssysteme GmbH
6.2.1
General Camera Settings
Video and audio connections
menu >
Camera
section >
Edit
button
Make the settings for each camera as required.
1
General settings
Click the tab.
2
Name:
Enter the name of the camera. The name must not contain
any special characters or end with a space.
3
Video loss
Activate this check box if a warning should be shown on
camera signal failure.
Note:
The malfunction relay is also activated if a relay output is
selected as a malfunction relay in the configuration (Inputs
and outputs menu, Relay tab).
4
Bilinx settings
Click the button to access the Bilinx camera navigation menu.
The Bilinx camera menu is displayed in the image window.
Note:
Only selectable for Bilinx-capable cameras.
5
Image properties
Set brightness, contrast, color and hue. You can see the
result of these settings in the camera image (
Hue
is only
active on NTSC cameras).
6
AGC
(AGC = automatic gain
control)
Activate this check box if the camera signal on the grabber
should be amplified.
7
Gain:
Manually correct the input level audio level at the grabber
using the slider.
Note:
Only possible when
AGC