DiBos/DiBos Micro
Connections | en
141
Bosch Sicherheitssysteme GmbH
Installation Guide
F.01U.033.308 | V7 | 2009.09
9.10
Connecting to AutoDome/SAE Dome
9.10.1
Connecting to Bosch Dome Cameras (Directly)
9.10.2
Connecting to Bosch Dome Cameras via Matrix Switch
1
Video system
4
AutoDome
2
Biphase
5
LTC matrix switch
3
Code multiplexer LTC 8569 or LTC
8570
1
5
3
4
2
2
2
NOTICE!
An LTC 8569 or LTC 8570 is needed if a Bosch LTC matrix switch is connected to the video
system at the same time as an AutoDome.
1
Video system
5
LTC 8x00
2
COM x
6
Biphase
3
Allegiant console cable LTC8506/00
7
AutoDome
4
Console port
1
5
2
6
3
7
4
NOTICE!
Valid CCL commands can be configured in DiBos. These pre-configured commands can then
be sent to the Allegiant matrix switch manually or automatically.