DiBos/DiBos Micro
Default Configuration | en
57
Bosch Sicherheitssysteme GmbH
Installation Guide
F.01U.033.308 | V7 | 2009.09
On command:
Here you enter the command that the camera sends when
motion detection is triggered.
Note:
The command can be found in the handbook for the camera
used.
Off command:
Here you enter the command that the camera sends when
motion detection has ended.
8
OK
The entries are saved.
NOTICE!
When configuring JPEG IP cameras, the following limits must be observed:
Image size and resolution limits:
–
A single JPEG image must not exceed 100 kB.
–
The image resolution must be in the aspect ratio 4:3 (e.g. 2048 x 1536).
–
The maximum resolution of the displayed images is limited to 2048 x 1536.
Recording settings limits:
–
The transmission images from analog and IP cameras are limited to a total of 900 images
per second.
–
The recording rate is limited to 50 Mbit/second (= 6.25 MB/second).