41
CHAPTER 4: Configuration
Conflicting Memory Size
There is a conflict between the memory listed in the configuration and the
Multiport Spooler VIII’s actual memory capacity. This is normally caused by
trying to save a configuration to the MPS-VIII after more memory has been
physically installed in the unit. First, save the revised configuration to a disk
file; if this is not possible, you will have to abandon your revisions and redo
them later. Use the UPDATE utility (see
Appendix C
) to update the
configuration saved in the MPS-VIII so that it reflects the added memory.
Then reload the new configuration from disk (or reload the old
configuration from the MPS-VIII and redo your changes) and try saving
the new configuration to the MPS-VIII again.
Transmission Error
An error occurred when the PC tried to transmit the revised configuration to
the Multiport Spooler VIII. Verify that the proper cables are securely attached
to the PC and to the MPS-VIII. If the MPS-VIII is cabled to one of the PC’s
serial ports (COM1, COM2, etc.), make sure that the serial port’s
communication parameters (data rate, parity, etc.) match those of the
MPS-VIII’s input port. Note that the PC’s serial port must be set for eight data
bits in order to send an MPS-VIII configuration to a PC file.
If any of these errors occurs, the configuration saved in the Multiport Spooler
VIII remains unchanged, and the unit is not reinitialized.
4.8.7 Q
UIT
Use
Quit
to exit the MPSCONF program. If you loaded a configuration, you
are asked whether you wish to save the configuration to disk or send it to the
Multiport Spooler VIII for saving in its static RAM.
Alternatively, you can abandon the configuration and return to DOS.