137
APPENDIX D: Sending Direct Commands to the MPS-VIII
D.3 Command Descriptions
This section takes a detailed look at each command.
For the Multiport Spooler VIII to detect and interpret a command, the
beginning of the command (the command-start character followed by “/”)
must be within the first 256 characters of a new task. Each transmission after
a timeout is considered a new task. This applies to all transmission methods
used.
If you use the UCTP to send commands, you do not need to wait for a
timeout, because the UCTP sends a Break signal before each command. The
Break signal forces the timeout to expire, thus allowing the next command
to be sent immediately.
Some third-party terminal-emulation packages also offer a break-signal
generation feature. Note that the Break key on a normal PC/XT or AT
keyboard does not generate a Break signal.
D.3.1 W
ILD
-C
ARD
C
HARACTERS
Wild-card characters permit groups of names to be selected with a single
entry. You can use them to select a port, a group of ports, or all ports. The
wild-card characters are:
*
Designates one or more characters
?
Designates a single character
For example, you can use these to select a port:
*
Select all the Multiport Spooler VIII ports configured as
output (serial or parallel) or serial bidirectional.
PORT#*
Select all the ports whose names consist of “PORT#” followed
by any other characters.
PORT#?
Select all the ports whose names consist of “PORT#” followed
by any single character.
PORT#?1
Select all the ports whose names consist of “PORT#” followed
by any single character followed by “1”.
The detailed command descriptions in
Section D.3.3
indicate when wild-card
characters may be used.