Table 2-15 KDC 100EXP Environmental Qualification Form (EQF)
DO-160G
Section
Conditions
Category
Notes
4.0
Temperature
B2
Operating Low Temperature = -45°C
Operating High Temperature = +70°C
8.0
Vibration
S Curve M
Table 2-16 KTP 73 Environmental Qualification Form (EQF)
DO-160G
Section
Conditions
Category
Notes
4.0
Temperature and Altitude
D2
-55°C/70°C, -55°C/70°C Short Term
-55°C/85°C Storage, 50,000 ft
In-flight Loss of Cooling (Not Applicable)
5.0
Temperature Variation
A
10°C per minute
6.0
Humidity
C
7.0
Operational Shocks and Crash Safety
A
6 g, 11 ms Pulse
Crash Safety (Impulse & Sustained) – no test
performed
8.0
Vibration
S(Curve M & T)
Zone 2 & Zone 5
9.0
Explosive Atmosphere
X
10.0
Waterproofness
S
11.0
Fluids Susceptibility
F
(Solvents & Cleaning Fluids, De-Icing Fluid)
12.0
Sand and Dust
X
13.0
Fungus Resistance
X
14.0
Salt Fog
S
15.0
Magnetic Effect
Z
16.0
Power Input
X
17.0
Voltage Spike
X
18.0
Audio-Frequency Conducted
Susceptibility
X
19.0
Induced Signal Susceptibility
X
20.0
Radio Frequency Susceptibility
(Radiated and Conducted)
X
21.0
Emission of Radio Frequency Energy
X
22.0
Lightning Induced Transient Susceptibility
X
23.0
Lightning Direct Effects
XX2A
24.0
Icing
X
25.0
Electrostatic Discharge
X
26.0
Flammability
C
Analysis Only