89000109-002
xVue Touch Installation Manual
Rev 2
Page B-6
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Figure B-6 KSD 100EXP LRU Interconnect Diagram
J71
KG 71
yW
40
41
A429_TX0_A
A429_TX0_B
34
35
A429_RX0_A
A429_RX0_B
J1
36
35
38
37
ŽŶĨŝŐƵƌĂƚŝŽŶDŽĚƵůĞ
wiring is to be contained
in
P2 unit backshell
ŽŶĨŝŐƵƌĂƚŝŽŶDŽĚƵůĞ
E6 (Red)
E7 (Black)
E4 (Green)
E2 (Blue)
E1 (Orange)
E3 (Yellow)
E5 (White)
APM_PWR_3P3VDC
APM_PWR_RTN
APM_CS_N
APM_SI
APM_SO
APM_SCLK
APM_WP_N
J2
KSD 100
yW
69
70
67
65
64
66
68
APM_PWR_3P3VDC
APM_PWR_RTN
APM_DATA_CS_N
APM_DATA_MOSI
APM_DATA_MISO
APM_CLK
APM_WP_N
KCP 100
yW
2
3
RS232_TX_OUT
RS232_RX_IN
77
76
KSD100_CTRL_PANEL_RS232_RX
KSD100_CTRL_PANEL_RS232_TX
J1
78
59
KSD100_CTRL_PANEL_PWR_15VDC
KSD100_CTRL_PANEL_PWR_RTN
9
8
15VDC_PWR_IN
15VDC_PWR_RTN
5
NOTES:
1
Single Conductor Wire
x
All wires shall be 22 AWG unless otherwise noted power wires
x
Wiring shall meet AS22759/16/XX/Y (Where XX is gauge and Y is color)
2
Twisted Shielded Pair/Triplet and Shielded Single Wire
x
All wires shall conform to ANSI/NEMA WC 27500
x
Do not remove any wiring between other active aircraft systems. Leave those systems installed as they are.
3
All shield grounds are to be grounded at the closest grounding point to their respective connectors . This includes connector grounding points.
For metallic backshells with grounding capability, ground shield directly to the backshell.
4
Drawing Symbols:
5 Over Braid will be installed between all wires from J2 of the KSD 100
yW
and P1 of the KCP 100
yW
. Terminate Braid within connector backshells.
- Single
-
Shielded Twisted Pair
ADAHRS1_A429_RX_A
ADAHRS1_A429_RX_B
ADAHRS1_A429_TX_A
ADAHRS1_A429_TX_B