For Use in Non-Certified Aircraft
Table 2-8 KDC 100EXP Data Converter Specifications
Characteristic
Specification
Dimensions
3.70 x 5.83 x 1.33 inches (93.98 x 148.08 x 37.78 mm)
Weight
0.99 lbs (0.45 kgs) Max. Weight
Temperature
-55 °C to +70°C
Altitude
55,000 ft.
Operating Voltage
14 to 28 VDC
Current Draw
(at 27.5 VDC)
80 mA Nominal, 25°C, after 2 minute warmup
200 mA Nominal, -55°C, after 2 minute warmup
700 mA Maximum, -55°C
Circuit Breaker
1 AMP for 28 VDC, 2 AMP for 14 VDC systems
Signal Inputs/Outputs
Serial CAN Bus
Cooling
Convection cooled. No external cooling required.
Connector
Male 15-pin
Certifications
TSO-C6d/ETSO-C6d (partial)
Table 2-9 KTP 73 Outside Air Temperature Probe Specifications
Characteristic
Specification
Dimensions
1.65 x 1.75 x 1.00 inches (41.91 x 44.45 x 25.4 mm)
Weight
0.17 lbs (0.07 kgs) Max. Weight
Current Draw
NA, not connected to the airplane power bus.
Operating Voltage
Connected to the ADAHRS, no interface to the airplane power.
Circuit Breaker
NA
Cooling
Mounted outside the airplane. No cooling required.
Connectors
5 ft. 3-conductor shielded wire lead, spliced into AC wiring harness.
Certifications
TSO-C106 (Incomplete)