89000109-002
xVue Touch Installation Manual
Rev 2
Page 2-10
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Notes:
1. Duplicate testing not required per DO-160G Section 16.6.1.2’s
Note
.
2. No test performed since the Line Replaceable Unit (LRU) has a metallic enclosure.
3. Analysis - Enclosure is constructed of metal on five sides
• Test – Polycarbonate display with 12 second vertical burn
• Test – Grip (Santoprene) with horizontal burn
• Test – Bezel Seal - Neoprene Cord with horizontal burn
4. Conducted Susceptibility (CS) testing was performed using DO-160E Cat A per FAA Policy PS-ACE-23-10.
5. Radiated Susceptibility (RS) testing was performed using the following levels per FAA Policy PS-ACE-23-10:
Table 2-10 KSD 100EXP Environmental Qualification Form (EQF)
DO-160G
Section
Conditions
Category
Notes
Frequency
DO-160G
Sect 20 Category
V/m
SW/CW
PM
100 - 200 MHz
Cat G
100
-
200 - 400 MHz
Cat G
100
-
400 - 700 MHz
Cat F
25
350
700 MHz – 1 GHz
Cat F
50
350
1 - 2 GHz
Cat D
50
500
2 - 4 GHz
Cat D
50
750
4 - 6 GHz
Cat D
50
750
6 - 8 GHz
Cat D
50
250
8 - 12 GHz
Cat D
75
750
12 - 18 GHz
Cat D
50
500