Card temperature critical
Card is overheating, which might result in decreased system performance
(for example, green dots, flickering, card not starting). You should halt
operations until the overheating problem is resolved.
Card temperature high
Temperature warning; this indicates that the card is warmer than normal
and that you should verify cooling and ventilation (for example, check for
anything obstructing the ventilation openings).
Upgrade dashboard messages
Message
Description
Error during firmware
upgrade. Firmware
upgrade cannot proceed
until legacy KXO (<3.00)
are removed from
frame B.
This message will appear on an expansion frame with expansion
enabled and with cards in Frame B running software or firmware
older than version 3.00. To upgrade these cards, transfer them to
Frame A.
Error during firmware
upgrade. Card presence
from frame B could not be
verified.
This message will appear as a side effect of the presence of cards in
Frame B running a version older than version 3.00. The upgrade
will not be permitted on any card in the frame until these cards are
removed from Frame B. To upgrade these cards, transfer them to
Frame A.
Error during firmware
upgrade. Duplicate IP has
been detected. We cannot
continue checking the
Firmware version.
This message will appear if duplicate IP addresses are detected
between different KXO cards in the frame. As long as this is the
case, no upgrade is possible. You must resolve the duplicate IP
address issue before resuming the upgrade.
Error during firmware
upgrade. The current
firmware version could
not be verified.
This message will appear if software cannot retrieve firmware
version from the cards. This may indicate an issue with the
hardware.
Error during safemode
upgrade. The current
safemode version could
not be verified.
This message will appear if software cannot retrieve safemode
version from the cards. This may indicate an issue with the
hardware.
Error during safemode
upgrade. Card presence
from frame B could not be
verified.
This message will appear as a side effect of the presence of cards in
Frame B running a version older than version 3.00. The upgrade
will not be permitted on any card in the frame until these cards are
removed from Frame B. To upgrade these cards, transfer them to
Frame A.
Cannot upgrade card in
this slot (if any). Please
remove card from [slot
number].
This message will appear on an expansion frame if Frame B
contains cards running software or firmware older than version
3.00. The upgrade will not be permitted on any card in the frame
until these cards are removed from Frame B. To upgrade these
cards, transfer them to Frame A.
Status dashboard messages
(continued)
Message
Description
Содержание Grass Valley Kaleido-X
Страница 19: ...19 Kaleido X 7RU Installation Service Manual Overview of the Kaleido X System Kaleido X 7RU System Overview...
Страница 22: ...22 Overview Functional Block Diagrams Simplified Signal Flow Diagram KX0 24Router...
Страница 40: ...40 Installation Ventilation...
Страница 100: ...100 IP Network Setup Network Considerations for a Multiviewer Cluster...
Страница 119: ...119 Kaleido X 7RU Installation Service Manual Internet Explorer s security warning Chrome s security warning...
Страница 123: ...123 Kaleido X 7RU Installation Service Manual 9 Click Finish A security warning appears...
Страница 152: ...152 System Configuration Enabling Options...
Страница 190: ...190 Maintenance Troubleshooting Disposal and Recycling Information...
Страница 215: ...215 Kaleido X 7RU Installation Service Manual...