138
System Configuration
Configuring the RCP-200
Configuring the RCP-200
The RCP-200 is shipped with an IP address of 10.0.3.200. On installation, you should consult
your system administrator and replace this address with an appropriate address for your
local network configuration (see
Configuring the RCP-200’s IP settings
your RCP-200 has an active connection to the network, you must then register the
multiviewers you want to operate from the RCP-200 (see
Specifying multiviewers for the
on page 138), and their respective
KX Router
logical routers (see
on page 138). Once this is completed, you will be able to control the
monitor wall from the RCP-200 (see
Configuring the RCP-200’s IP settings
To assign an IP address to the RCP-200
1 Press the CONFIG button, located between the two screens on the front of the RCP-200.
2 Touch the COMM category at the top of the right-hand screen.
3 Touch the ETHERNET tab on the right-hand screen.
4 In the SELECT area, rotate the leftmost control knob to select IP ADDRESS.
5 Use the four control knobs in the CHANGE area to set the new address.
The current address is displayed in the CURRENT box for reference, and the new
address you are setting appears in the MODIFIED box, as well as at the controls.
6 Press the SAVE control knob to store the new address.
7 Repeat from
to configure the NETWORK MASK and GATEWAY settings.
8 Press the RESTART control knob to apply the changes.
The panel will go dark for about 15 seconds before the startup screens appear.
Specifying multiviewers for the RCP-200
To specify a multiviewer for the RCP-200
1 Press the CONFIG button, located between the two screens on the front of the RCP-200.
2 Touch the COMM category on the right-hand screen.
3 Touch the KALEIDO DISCOVERY tab on the right-hand screen.
4 Use the four control knobs in the ADD TO LIST area to dial in the IP address of the
multiviewer you want to operate.
The address appears in the TO ADD box.
5 Press the ADD control knob.
The multiviewer’s IP address appears in the LOOKUP LIST area.
6 Press the CONFIG button, located between the two screens on the front of the RCP-200
to end the configuration process and return to normal operation.
Specifying lookup servers for the RCP-200
The RCP-200 needs to connect to a lookup server in order to control devices, including a
multiviewer’s
KX router
logical router.
Содержание Grass Valley Kaleido-X
Страница 19: ...19 Kaleido X 7RU Installation Service Manual Overview of the Kaleido X System Kaleido X 7RU System Overview...
Страница 22: ...22 Overview Functional Block Diagrams Simplified Signal Flow Diagram KX0 24Router...
Страница 40: ...40 Installation Ventilation...
Страница 100: ...100 IP Network Setup Network Considerations for a Multiviewer Cluster...
Страница 119: ...119 Kaleido X 7RU Installation Service Manual Internet Explorer s security warning Chrome s security warning...
Страница 123: ...123 Kaleido X 7RU Installation Service Manual 9 Click Finish A security warning appears...
Страница 152: ...152 System Configuration Enabling Options...
Страница 190: ...190 Maintenance Troubleshooting Disposal and Recycling Information...
Страница 215: ...215 Kaleido X 7RU Installation Service Manual...