6) Encoder TEST:
The motor must run when testing the encoder.
Access the ENCODER/FREQUENCY INPUTS MENU; set the source of the encoder signal
used as a speed feedback (Encoder A in terminal board, Encoder B from
ES836
or
ES913
option board); enter the number of pulse/rev and the number of the encoder channels (more
details are given in the relevant section in the
Installation Instructions Manual
).
In MOTOR CONTROL MENU, set the parameter relating to the speed feedback from encoder:
C012
= Yes.
Access the AUTOTUNE MENU and set parameter
I073
(Select Autotune Type) as “Encoder
Tune”. Use the
ESC
key to confirm changes. Close the
ENABLE
command and wait until
encoder tune is complete (“W32 Open Enable” is displayed).
Once encoder tune is complete, the display will show one of the following messages:
“
W31
Encoder Ok”; the speed feedback is correct. If the speed detected by the encoder is
opposite to the desired speed, the drive will automatically reverse the feedback sign (parameter
C199
).
“
A059
Encoder Fault”; the speed detected from the encoder is not consistent with the control
speed. Possible causes:
- Wrong number of pls/rev of the encoder
- Wrong power supply of the Encoder (e.g. +5V instead of +24V): check the encoder ratings
and the position of jumpers and dip-switches for the encoder supply in the optional encoder
board
- Wrong configuration of the dip-switches for the encoder selection (push-pull or line-driver
encoder) in the optional encoder board
- No connection to the encoder channel (check wiring)
- At least one Encoder channel is faulty (replace the encoder).
7) Autotune of the
stator resistance and
leakage inductance:
First remove the
ENABLE
command, then access the MOTOR CONTROL MENU and set
I073
(1: Motor Tune) and
I074
= (0: All Ctrl no rotation) . Use the
ESC
key to accept changes.
Close the
ENABLE
command and wait until autotune is complete (warning “
W32
Open
Enable” is displayed). The drive has computed and saved the values for
C022
and
C023
. If
alarm “
A097
Motor wires KO“ trips, check the motor wiring. If alarm “A065 Autotune KO” trips,
this means that the
ENABLE
command has opened before autotune was completed. In this
case, reset the drive sending a command from terminal MDI3, or press the
RESET
key in the
display/keypad and perform the autotune procedure again.
8) Autotune of the
current loop:
First remove the
ENABLE
command, , then access the AUTOTUNE MENU and set
I073
(1:
Motor Tune) and
I074
= (1: FOC Auto no rotation). Use the
ESC
key to accept changes. Close
the
ENABLE
command and wait until autotune is complete (warning “
W32
Open Enable” is
displayed). The drive has computed and saved the values for
P155
and
P156
. If alarm “
A065
Autotune KO” trips, this means that the
ENABLE
command has opened before autotune was
completed or that the autotune algorithm failed. In this case, reset the drive sending a
command from terminal MDI3, or press the
RESET
key in the display/keypad and perform the
autotune procedure again.
NOTE
If the
ENABLE
command was not opened before autotune was over, decrease by 5% the no-
load current value set in
C021
and perform autotune again.
Содержание SINUS PENTA
Страница 142: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 142 452 Figure 21 Curve voltage speed implemented by AO1 Example 5 ...
Страница 184: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 184 452 Figure 33 ANALOG Mode Figure 34 DOUBLE DIGITAL Mode ...
Страница 185: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 185 452 Figure 35 General structure of the parameterization of a digital output ...
Страница 348: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 348 452 Figure 57 Power Down Example ...
Страница 435: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 435 452 ...