C034b (C077b, C120b) VTC Torque Boost for Negative Reference
C034b (mot. n.1)
C077b (mot. n.2)
C120b (mot. n.3)
Range
–500
500
–50.0
50.0 %
Default
0%
Level
ENGINEERING
Address
1205, 1207, 1209
Control
VTC
Function
VTC control: determines the increase of the torque at low rpm with a negative
speed/torque reference.
C035 (C078,C121) Torque Curve Increment Boost 0
C035 (Motor 1)
C078 (Motor 2)
C121 (Motor 3)
Range
–100
+100
–100
+100 %
Default
See Table 75 and Table 79
Level
ADVANCED
Address
1035, 1078, 1121
Control
IFD
Function
Torque compensation at low rpm. Determines how output voltage varies at 5% of
the motor rated frequency with respect to the voltage obtained with a constant
V/f pattern (constant voltage frequency).
C036 (C079,C122) Torque Curve Increment Boost 1
C036 (Motor 1)
C079 (Motor 2)
C122 (Motor 3)
Range
–100
+400
–100
+400 %
Default
See Table 75 and Table 79
Level
ADVANCED
Address
1036, 1079, 1122
Control
IFD
Function
Torque compensation at preset frequency (parameter
C037
for motor 1,
C080
for
motor 2 and
C123
for motor 3). Determines how output voltage varies at preset
frequency with respect to voltage obtained with a constant V/f pattern (constant
voltage frequency).
C037 (C080,C123) RPM Relating to C36 (C079,C122) (Frequency for Application of Boost 1)
C037 (Motor 1)
C080 (Motor 2)
C123 (Motor 3)
Range
6
99
6
99 %
Default
See Table 75 and Table 79
Level
ADVANCED
Address
1037,1080,1123
Control
IFD
Function
Frequency for application of voltage Boost with parameter
C036
for motor 1,
parameter
C079
for motor 2 and parameter
C122
for motor 3. This is expressed as
a percentage of the motor rated frequency.
Содержание SINUS PENTA
Страница 142: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 142 452 Figure 21 Curve voltage speed implemented by AO1 Example 5 ...
Страница 184: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 184 452 Figure 33 ANALOG Mode Figure 34 DOUBLE DIGITAL Mode ...
Страница 185: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 185 452 Figure 35 General structure of the parameterization of a digital output ...
Страница 348: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 348 452 Figure 57 Power Down Example ...
Страница 435: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 435 452 ...