SINUS PENTA
PROGRAMMING
INSTRUCTIONS
132/452
P155 (P162, P169) Current Regulator Proportional Constant
P155 (Motor n.1)
P162 (Motor n.2)
P169 (Motor n.3)
Range
0
65000
0.00
650.00
Default
300
3.00
Level
ENGINEERING
Address
755
762
769
Control
FOC
Function
Kp
Proportional coefficient of
PI
current regulator Id and Iq in field rotary
reference for motor n.1
(
P162
and
P169
relate to motors 2 and 3).
The regulator’s structure is as follows:
error =
Set_Point
–
Measure
;
integral_status
=
integral_status
+
error
*
Ki
*
Ts
;
Output
=
Kp
*
error
+
integral_status
;
where Kp is the proportional coefficient
Ki
is the integral coefficient = 1/Ti , where Ti is the integral time
Ts
is the regulator operating time (ranging from 200 to 400 microseconds
based on carrier frequency).
NOTE
This parameter is
automatically computed and saved
when the Autotuning procedure
is performed (see the AUTOTUNE MENU).
P156 (P163, P170) Current Regulator Integral Time
P156 (Motor n.1)
P163 (Motor n.2)
P170 (Motor n.3)
Range
1
32000
1.0
32000. (Disabled)
Default
200
20.0 ms
Level
ENGINEERING
Address
756
763 (motor n.2)
770 (motor n.3)
Control
FOC
Function
Ti
Integral time of
PI
current regulator Id and Iq in the field rotary reference for
motor n.1
(
P166
and
P170
relate to motors 2 and 3).
The regulator’s structure is as follows:
error =
Set_Point
–
Measure
;
integral_status
=
integral_status
+
error
*
Ki
*
Ts
;
Output
=
Kp
*
error
+
integral_status
;
where Kp is the proportional coefficient
Ki
is the integral coefficient = 1/Ti , where Ti is the integral time
Ts
is the regulator operating time (ranging from 200 to 400 microseconds
based on carrier frequency).
NOTE
This parameter is
automatically computed and saved
when the Autotuning procedure
is performed (see the AUTOTUNE MENU).
Содержание SINUS PENTA
Страница 142: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 142 452 Figure 21 Curve voltage speed implemented by AO1 Example 5 ...
Страница 184: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 184 452 Figure 33 ANALOG Mode Figure 34 DOUBLE DIGITAL Mode ...
Страница 185: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 185 452 Figure 35 General structure of the parameterization of a digital output ...
Страница 348: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 348 452 Figure 57 Power Down Example ...
Страница 435: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 435 452 ...