SINUS PENTA
PROGRAMMING
INSTRUCTIONS
392/452
C336 (C343, C350, C357) Days of the Week of the Activation of the Timed Flag TFL1 (TFL2, TFL3, TFL4)
C336
C343
C350
C357
Range
0000000b
1111111b
binary
0
127
Default
0
0
Level
ADVANCED
Address
277(284, 291, 298)
Function
Sets the second of deactivation of the timed flag
TFL1 (TFL2, TFL3, TFL4)
.
Every bit corresponds to a day of the week: bit 1 corresponds to Monday, bit 7
corresponds to Sunday. Example:
1111100: flag TLF1 will activate every day of the week but Saturday and
Sunday.
0000000: the flag will never activate.
1111111: the flag will activate every day.