MEASURE
CONTROL
FROM
PT100
2 6.1.
Overview
This menu relates to ES847 control board. It can be viewed only if
R023
(I/O board setting) = PT100 (see the
EXPANSION BOARD CONFIGURATION MENU).
The analog inputs can be linked to measure sensors.
NOTE
Set DIP-Switches 1 and 2 as follows for proper data acquisition from PT100:
O N
1
SW1
2
3
O N
1
4
5
6
7
O N
1
8
O N
1
SW1
2
3
O N
1
4
5
6
7
O N
1
8
O N
1
2
3
O N
1
4
5
6
7
O N
1
8
O N
1
2
3
O N
1
4
5
6
7
O N
1
8
SW2
2 6.2.
List of Parameters P318 to P325
Table 51: List of parameters P318 to P325.
Parameter
FUNCTION
User Level
DEFAULT
VALUES
MODBUS
Address
P320
Channel 1: measure mode
ADVANCE
D
0: no input
920
P321
Channel 1: measure offset
ADVANCE
D
0.0 °C
921
P322
Channel 2: measure mode
ADVANCE
D
0: no input
922
P323
Channel 2: measure offset
ADVANCE
D
0.0 °C
923
P324
Channel 3: measure mode
ADVANCE
D
0: no input
924
P325
Channel 3: mesaure offset
ADVANCE
D
0.0 °C
925
P326
Channel 4: measure mode
ADVANCE
D
0: no input
926
P327
Channel 4: mesaure offset
ADVANCE
D
0.0 °C
927
Содержание SINUS PENTA
Страница 142: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 142 452 Figure 21 Curve voltage speed implemented by AO1 Example 5 ...
Страница 184: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 184 452 Figure 33 ANALOG Mode Figure 34 DOUBLE DIGITAL Mode ...
Страница 185: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 185 452 Figure 35 General structure of the parameterization of a digital output ...
Страница 348: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 348 452 Figure 57 Power Down Example ...
Страница 435: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 435 452 ...