PROGRAMMING
INSTRUCTIONS
SINUS PENTA
191/452
2 4.4.
List of Parameters P270 to P305
Table 49: List of parameters P270 to P305.
Parameter
FUNCTION
User Level
DEFAULT VALUES
MODBUS
Address
P270
MDO1: Digital output mode
ADVANCE
D
3:ANALOG
870
P271
MDO1: Selecting variable A
ADVANCE
D
A71: Speed
871
P272
MDO1: Selecting variable B
ADVANCE
D
A71: Speed
872
P273
MDO1: Testing variable A
ADVANCE
D
0:
>
873
P274
MDO1: Testing variable B
ADVANCE
D
3:
≤
874
P275
MDO1: Comparing value for Test A
ADVANCE
D
50 rpm
875
P276
MDO1: Comparing value for Test B
ADVANCE
D
10 rpm
876
P277
MDO1: Function applied to the result of the 2 tests
ADVANCE
D
1: (A) SET (B)
RESET
877
P277a
MDO1: Selecting variable C
ADVANCE
D
0: Disable
642
P277b
MDO1: Function applied to the result of f(A,B) C
ADVANCE
D
0: f(A,B) OR C
643
P278
MDO1: Output logic level
ADVANCE
D
1: TRUE
878
P279
MDO2: Digital output mode
ADVANCE
D
6: BRAKE
879
P280
MDO2: Selecting variable A
ADVANCE
D
A81: Trq Output
880
P281
MDO2: Selecting variable B
ADVANCE
D
A71: Speed
881
P282
MDO2: Testing variable A
ADVANCE
D
0: >
882
P283
MDO2: Testing variable B
ADVANCE
D
3:
≤
883
P284
MDO2: Comparing value for Test A
ADVANCE
D
20%
884
P285
MDO2: Comparing value for Test B
ADVANCE
D
50 rpm
885
P286
MDO2: Function applied to the result of the 2 tests
ADVANCE
D
1: (A) SET (B)
RESET
886
P286a
MDO2: Selecting variable C
ADVANCE
D
0: Disable
644
P286b
MDO2: Function applied to the result of f(A,B) C
ADVANCE
D
0: f(A,B) OR C
645
P287
MDO2: Output logic level
ADVANCE
D
1: TRUE
887
P288
MDO3: Digital output mode
ADVANCE
D
1: DIGITAL
888
P289
MDO3: Selecting variable A
ADVANCE
D
D3: Inverter Alarm
889
P290
MDO3: Selecting variable B
ADVANCE
D
D3: Inverter Alarm
890
P291
MDO3: Testing variable A
ADVANCE
D
0: >
891
P292
MDO3: Testing variable B
ADVANCE
D
0: >
892
P293
MDO3: Comparing value for Test A
ADVANCE
D
0
893
P294
MDO3: Comparing value for Test B
ADVANCE
D
0
894
Содержание SINUS PENTA
Страница 142: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 142 452 Figure 21 Curve voltage speed implemented by AO1 Example 5 ...
Страница 184: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 184 452 Figure 33 ANALOG Mode Figure 34 DOUBLE DIGITAL Mode ...
Страница 185: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 185 452 Figure 35 General structure of the parameterization of a digital output ...
Страница 348: ...SINUS PENTA PROGRAMMING INSTRUCTIONS 348 452 Figure 57 Power Down Example ...
Страница 435: ...PROGRAMMING INSTRUCTIONS SINUS PENTA 435 452 ...