![Baumuller b maXX 5500 Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/baumuller/b-maxx-5500/b-maxx-5500_instruction-handbook-manual_2711410098.webp)
Electrical data basic units
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
Baumüller Nürnberg GmbH
98
3.4
m
With charging resistor BM57XX-X
R
/BM57XX-X
S
/BM57XX-X
W
BM5
7
6
6
14)
Rated input power
1)2)
363 kVA
Rated input current
1)2)
(I
eff
)
523 A
Total harmonic distortion input current
1)2)
(THD
I
)
73%
16)
Max. input current
2)
(I
eff
)
455 A
Rated DC link voltage
1)
540 V
DC
17)
DC link capacitance (internal)
10,8 mF
DC link capacitance (external), permitted
prohibited
15)
DC link discharging time (internal DC link capacitance)
1840 s
Waiting time between two switching-on operations
55 s
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
13)
0 Hz to 450 Hz
Rated output current
1)5)6)7)14)
(I
AC
)
at 4 kHz
4)
450 A
Rated output current
1)5)6)7)14)
(I
AC
)
at 8 kHz
4)
305 A
Output peak current
1)5)6)8)14)
(I
AC
)
at 4 kHz
4)
450 A
Output peak current
1)5)6)8)14)
(I
AC
)
at 8 kHz
4)
305 A
Max. peak current period
8)
No limit
Connected load DC link terminals
Max. 160 kW
Brake resistor current, permitted (Î)
Max. 236 A
Brake resistor, external
3,33
Brake resistor threshold (Û)
11)
780 V
Brake resistor peak power
183 kW
Permitted continuous brake resistor power external
130 kW
Power loss referring to power input
4800 W
Power loss referring to control voltage
93 W
Power loss of device fan referring to 230 V
AC
9)
174 W
Current of integrated brake control
Max. 8.0 A
10)
Cooling air requirement device internal space
200 m
3
/h