Accessories and Spare Parts
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
289
11
Type code
Figure 119:
Type code power choke
The listed chokes are specified for the operation at 400 V /50 Hz or 480 V / 60 Hz.
At a power supply voltage of 400 V and a frequency of 50 Hz at rated current the chokes
have a short-circuit voltage > 3% of the power supply voltage.
UL approval
The chokes are design-tested in accordance with UL (e.g. UL1561) and signified by the
„
ú“
" symbol.
B K X - XXXX / XXX - XXX
Baumüller
Commuation choke
No. of phases
1: Single phase choke
3: Three phase choke
Rated AC current I
eff
Development status/design
001: Connection copper bar, overload factor 1,1
002: Connection terminal, overload factor 1,1
101: Connection copper bar, overload factor 2
102: Connection terminal, overload factor 2
DC set value
- Single phase choke: 1.0 x I
eff
- Three phase choke: 1,22 x I
eff
NOTE
Power chokes are not necessary for following devices:
BM551X, BM5523, BM5524, BM5525
and
BM5XXX-X
R
/BM5XXX-X
S
/BM5XXX-X
W
.
I
rated AC
Induc-
tance
Type code
Part No.
type -101,
connection
copper bar
Part No.
type -102,
connection
terminal
For devices
24 A
1,22 mH BK3-0024/0029
-
456715
BM5526
53 A
0,55 mH BK3-0053/0070
-
456717
BM5632
82 A
0,36 mH BK3-0082/0100
-
456718
BM5641
95 A
0,31 mH BK3-0095/0116
-
456720
BM5642
125 A
0,23 mH BK3-0125/0153
-
456722
BM5650
160 A
0,18 mH BK3-0160/0196
-
456723
BM5651
190 A
0,15 mH BK3-0190/0232
456725
-
BM5652
240 A
0,12 mH BK3-0240/0294
456728
-
BM5661
285 A
0,10 mH BK3-0285/0350
456729
-
BM5662