3.4
3.4.1.7 Electrical data BM557X universal units
BM5
5
7
2 - A/F
BM5
5
7
3 - A/F
Rated input power
1)2)
328 kVA
412 kVA
Rated input current
1)2)
(I
eff
)
474 A
594 A
Total harmonic distortion input current
1)2)
(THD
I
)
54 %
Max. input current
2)
(I
eff
)
602 A
760 A
DC link rated voltage
1)
540 V
DC
DC link capacitance (internal)
19.8 mF
DC link capacitance (external), permitted
DC link discharging time
(internal DC link capacitance)
100 s
120 s
Waiting time between two switching-on operations
None
Output voltage
1)3)
(U
AC
)
3 x 0 V bis 3 x 370 V
Output frequency at 4 kHz
14)
0 Hz bis 450 Hz
Rated output current
1)5)6)7)13)15)
(I
AC
)
at 4 kHz
4)
450 A
615 A
Rated output current
1)5)6)7)13)15)
(I
AC
)
at 8 kHz
4)
338 A
420 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 4 kHz
4)
585 A
800 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 8 kHz
4)
439 A
545 A
Max. peak current period
9)
60 s
Connected load DC link terminals
Max. 250 kW
Max. 315 kW
Brake resistor current, permitted (Î)
Max. 300 A
Brake resistor, external
2.6
Brake resistor threshold (Û)
12)
780 V
Brake resistor peak power
234 kW
Permitted continuous brake resistor power external
180 kW
Power loss referring to power input
4700 W
6450 W
Power loss referring to control voltage
116 W
Power loss of the device fan referring to 400 V
AC
Max. 540 W
Current of integrated brake control
Max. 8.0 A
11)
Cooling air requirement power heatsink
1000 m
3
/h
Cooling air requirement device internal space
250 m
3
/h