Technical Data
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
81
3
m
With charging resistor BM556X-X
R
/BM556X-X
S
/BM556X-X
W
BM5
5
6
2
BM5
5
6
3
BM5
5
6
6
14)
Rated input power
1)2)
184 kVA
227 kVA
351 kVA
Rated input current
1)2)
(I
eff
)
267 A
328 A
506 A
Total harmonic distortion input current
1)2)
(THD
I
)
110 %
17)
112 %
17)
115 %
17)
Max. input current
2)
(I
eff
)
338 A
415 A
628 A
Rated DC link voltage
1)
540 V
DC
18)
DC link capacitance (internal)
10810
F
DC link capacitance (external), permitted
Prohibited
16)
DC link discharging time (internal DC link capacitance)
1850 s
Waiting period between two switching-on operations
600 s
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
12)
0 Hz to 450 Hz
Rated output current
1)5)6)7)15)
(I
AC
)
at 4 kHz
4)
250 A
300 A
350 A
Rated output current
1)5)6)7)15)
(I
AC
)
at 8 kHz
4)
200 A
240 A
240 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 4 kHz
4)
325 A
390 A
450 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 8 kHz
4)
260 A
312 A
312 A
Max. peak current period
8)
60 s
Connected load DC link terminals
Max. 160 kW
Brake resistor current, permitted (Î)
Max. 230 A
Max. 236 A
Brake resistor external
3.4
3.33
Brake resistor threshold (Û)
11)
780 V
Brake resistor peak power
179 kW
183 kW
Permitted continuous brake resistor power external
130 kW
Power loss referring to power input
3960 W
4800 W
Power loss referring to control voltage
93 W
Power loss of the device fan referring to 230 V
AC
9)
174 W
Current of integrated brake control
Max. 8.0 A
10)
Cooling air requirement power heatsink
450 m
3
/h
Cooling air requirement device internal space
200 m
3
/h