![Baumuller b maXX 5500 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/baumuller/b-maxx-5500/b-maxx-5500_instruction-handbook-manual_2711410069.webp)
Technical Data
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
69
3
m
With charging resistor BM553X-X
R
/BM553X-X
S
/BM553X-X
W
BM5
5
3
4
BM5
5
3
5
Rated input power
1)2)
38 kVA
62 kVA
Rated input current
1)2)
(I
eff
)
55.0 A
89.0 A
Total harmonic distortion input current (THD
I
)
1)2)
107 %
14)
112 %
14)
Max. input current
2)
(I
eff
)
99.0 A
162.0 A
Rated DC link voltage
1)
(U
DC
)
540 V
DC
15)
DC link capacitance (internal)
1640
F
2000
F
DC link discharging time (internal DC link capacitance)
280 s
340 s
Waiting period between two switching-on operations
(no external DC link capacitance)
95 s
115 s
Max. permitted DC link capacitance (in external)
10810 µF
Waiting period between two switching-on operations
(with max. permitted DC link capacitance)
600 s
13)
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
10)
0 Hz to 450 Hz
Rated output current
1)5)6)7)12)
(I
AC
)
at 4 kHz
4)
45,0 A
60.0 A
Rated output current
1)5)6)7)12)
(I
AC
)
at 8 kHz
4)
36,0 A
48.0 A
Output peak current
1)5)6)8)12)
(I
AC
)
at 4 kHz
4)
90,0 A
Output peak current
1)5)6)8)12)
(I
AC
)
at 8 kHz
4)
72,0 A
Max. peak current period
8)
60 s
Power supply DC link terminals
Max. 10,0 kW
Brake resistor current, permitted (Î)
Max. 50.0 A
Brake resistor, external
16
Brake resistor threshold (Û)
780 V
Brake resistor peak power
40 kW
Permitted continuous brake resistor power external
10 kW
Power loss referring to power input
600 W
840 W
Power input referring to control voltage
58 W
Current of the integrated brake control
Max. 8.0 A
11)