Cabling
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
Baumüller Nürnberg GmbH
254
11.1
m
Motor cable with HIPERFACE DSL
®
28 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
white
Figure 108:
Motor cable with HIPERFACE DSL
®
28 A
Cable: 4G4.0+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned
Motor side:
Circular metal connector speedtec
®
M40 9-pin
Outside shielding and inside shielding must be wired separately.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219
Connect inside shielding with the connector housing.
Circular connector
speedtec
®
M40
Type of stranding
Unconnected
wires
Cross section of wire
U
U
4 mm² / black / U
V
V
4 mm² / black / V
W
W
4 mm² / black / W
GN/GE
4 mm² / green-yellow
+
B+
1.0 mm² / black
-
B-
1.0 mm² / black
H
DSL+
22 AWG / white
L
DSL-
22 AWG / blue
Housing
-
Outside shielding
Housing
-
Inside shielding