![Baumuller b maXX 5500 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/baumuller/b-maxx-5500/b-maxx-5500_instruction-handbook-manual_2711410080.webp)
Electrical data basic units
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
Baumüller Nürnberg GmbH
80
3.4
3.4.1.6 Electrical data BM556X universal units
m
Without charging resistor BM556X-X
T
/BM556X-X
G
/BM556X-X
I
BM5
5
6
2
BM5
5
6
3
BM5
5
6
6
14)
Rated input power
1)2)
164 kVA
204 kVA
238 kVA
Rated input current
1)2)
(I
eff
)
237 A
295 A
344 A
Total harmonic distortion input current
1)2)
(THD
I
)
43 %
50 %
50 %
Max. input current
2)
(I
eff
)
320 A
395 A
455 A
Rated DC link voltage
1)
540 V
DC
DC link capacitance (internal)
5170
F
6110
F
8460
F
DC link capacitance (external), permitted
DC link discharging time (internal DC link capacitance)
120 s
170 s
220 s
Waiting period between two switching-on operations
None
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
12)
0 Hz to 450 Hz
Rated output current
1)5)6)7)15)
(I
AC
)
at 4 kHz
4)
250 A
300 A
350 A
Rated output current
1)5)6)7)15)
(I
AC
)
at 8 kHz
4)
200 A
240 A
240 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 4 kHz
4)
325 A
390 A
450 A
Output peak current
1)5)6)8)15)
(I
AC
)
at 8 kHz
4)
260 A
312 A
312 A
Max. peak current period
8)
60 s
Connected load DC link terminals
Max. 160 kW
Brake resistor current, permitted (Î)
Max. 230 A
Max. 236 A
Brake resistor external
3.4
3.33
Brake resistor threshold (Û)
11)
780 V
Brake resistor peak power
179 kW
183 kW
Permitted continuous brake resistor power external
130 kW
Power loss referring to power input
3960 W
4800 W
Power loss referring to control voltage
93 W
Power loss of the device fan referring to 230 V
AC
9)
174 W
Current of integrated brake control
Max. 8.0 A
10)
Cooling air requirement power heatsink
450 m
3
/h
Cooling air requirement device internal space
200 m
3
/h