Technical Data
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
89
3
3.4.2.2 Electrical data BM564X acceleration units
BM564
1
BM564
2
Rated input power
1)2)
57 KVA
65 kVA
Rated input current
1)2)
(I
eff
)
82 A
95 A
Distortion factor of the input current
1)2)
(THD
I
)
50 %
50 %
Max. input current
2)
(I
eff
)
164 A
190 A
DC link rated voltage
1)
540 V
DC
DC link capacitance (internal)
3055
F
DC link capacitance (external), permitted
DC link discharging time (internal DC link capacitance)
70 s
Waiting time between two switching-on operations
None
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
11)
0 Hz to 450 Hz
Rated output current
1)5)6)7)13)
(I
AC
)
at 4 kHz
4)
85 A
100 A
Rated output current
1)5)6)7)13)
(I
AC
)
at 8 kHz
4)
64 A
75 A
Output peak current
1)5)6)8)13)
(I
AC
)
at 4 kHz
4)
170 A
200 A
Output peak current
1)5)6)8)13)
(I
AC
)
at 8 kHz
4)
128 A
150 A
Max. peak current period
8) 9)
1.25 s
Connected load DC link terminals
10)
Max. 60 kW / 120 kW (1 s)
Brake resistor current, permitted (Î)
Max. 100 A
Brake resistor, external
v
7.4
14)
Brake resistor threshold (Û)
780 V
Brake resistor peak power
80 kW
Permitted continuous brake resistor power external
58 kW
Power loss referring to power input
1350 W
Power input referring to control voltage
112 W
Power input of the fan of the device referring to 230 V
AC
9)
87 W
Current of integrated brake control
Max. 8.0 A
12)
Cooling air requirement device internal space
60 m
3
/h
Requirements to water cooling
Refer to