7 0
C H A N GE PARA METERS
6.1.1 7 C ALIBRA TIO N / Motor 1 or 2 se
l
ect PIN 2 0
A
ll
the a
l
terab
l
e parameters conta
i
ned
i
n the C H A N GE P ARA METERS reduced menu may have 2 va
l
ue
sett
i
ngs. (M O T OR 1 and M O T OR 2). Th
i
s w
i
ndo w se
l
ects the act
i
ve set. The act
i
ve set
i
s a
l
w ays the one
ava
il
ab
l
e
i
n the C H A N GE PAR A ME TERS menu d
i
sp
l
ay. The pass
i
ve set can be v
i
e w ed and mod
i
f
i
ed
i
n the
conf
i
gurat
i
on menu. See 1 3.1 3.1 DRIV E PERS O N ALIT Y / PA SSIV E M O T OR SET.
See 1 1.1 DISPL A Y FUN C TIO NS / Reduced menu enab
e. The pass
i
ve motor set of parameters
i
s the same as
the REDU CED MENU.
Th
i
s PIN can of course be conf
i
gured to be set by a d
i
g
i
ta
l
i
nput for externa
l
set se
l
ect
i
on. It may a
l
so be
used as a d
i
agnost
i
c to sho w w h
i
ch set
i
s act
i
ve, and may be connected to a d
i
g
i
ta
l
output
i
f des
i
red.
Ru
l
es of operat
i
on.
1) Motor 1 and 2 ca
li
brat
i
on parameters are N O T overwr
i
tten
i
f the
f
ac
to
r
y d
e
f
a
u
l
t
parameters are restored.
2) The M O T OR 1, 2 SELE C T parameter
i
s N O T over wr
i
tten
i
f the
f
ac
to
r
y d
e
f
a
u
l
t
parameters are restored.
Th
i
s means that the PL/X defau
l
t po w er up (4-KEY RESET) w
ill
not affect the
p
r
e
v
a
ili
ng
ca
li
brat
i
on
parameters. PINs 2 – 2 0, 1 0 0)FIELD V OLTS OP % and 6 8 0)Iarm BURDEN O H MS,
i
n both the act
i
ve set and
the pass
i
ve set. A
ll
other parameters are restored to the factory defau
l
ts.
See 5.1.3 Restor
See 4.5.4 PA SSIV E M O T OR defau
See 1 3.1 3.2 DRIV E PERS O N ALIT Y / Rec
There
i
s a c
l
ass of parameters that are prevented from be
i
ng a
l
tered by the keys dur
i
ng motor runn
i
ng. These
are
i
nd
i
cated
i
n the PIN number tab
l
es at the back of the manua
l
by a
l
etter S (ST OP DRIV E T O A DJ UST)
i
n
the ‘Property’ co
l
umn. See 1 5 PIN number tab
If 2 0)M O T OR 1, 2 SELEC T
i
s a
l
tered dur
i
ng runn
i
ng, then any c
l
ass ‘S’ parameters
i
n the DRIV E
PERS O N ALIT Y / PA SSIV E M O T OR SE T that d
i
ffer from the
i
r counterparts
i
n the A C TIV E set w
ill
not become
act
i
ve unt
il
the next ST OP sequence.
Th
i
s funct
i
ona
li
ty g
i
ves an extra
l
eve
l
of safety but st
ill
a
ll
o w s dynam
i
c a
l
terat
i
on of most of the
i
mportant
parameters, dur
i
ng runn
i
ng, by one d
i
g
i
ta
l
i
nput.
C ALIBRA TIO N 3
2 0)M O T OR 1,2 SELE C T
2 0)M O T OR 1,2 SELE C T
M O T OR 1
PAR A ME TER
RA N GE
DEF A ULT
PIN
M O T OR 1, 2 SELE C T
M O T OR 1 or M O T OR 2 M O T OR 1
2 0
Se
l
ects motor 1 or motor 2
reduced menu as act
i
ve.
R
R
Содержание PLX
Страница 2: ...2 Contents ...
Страница 202: ......