
7-10 Parameter Descriptions
MN765
Block Title Parameter (Number)
Selection (Value)
Parameter Name and Description
OUTPUT
SETUP
(Continued)
ANA OUT1 SIGNAL
(1511)
ANA OUT2 SIGNAL
(1514)
(Continued)
Analog In2 (20) Scaled value of the analog input 2 signal value, range depends on input type
P1408.
Opt1 Ana In1 (21) Scaled value of option board 1 analog input 1 signal value, range depends on input
type selected.
Opt1 Ana In2 (22) Scaled value of option board 1 analog input 2 signal value, range depends on input
type selected.
Opt2 Ana In1 (23) Scaled value of option board 2 analog input 1 signal value, range depends on input
type selected.
Opt2 Ana In2 (24) Scaled value of option board 2 analog input 2 signal value, range depends on input
type selected.
Proc Feedforward (25) Scaled value of the process feedforward signal, range is -100% to 100% of
Process Feedforward signal.
Proc Feedback (26) Scaled value of the process feedback signal, range is -100% to 100% of Process
Feedback signal.
Proc Setpoint (27) Scaled value of the process setpoint source, range is -100% to 100% of Process
Setpoint signal.
Electric Angle (28) Scaled value of the electrical angle of shaft, range is from 0-359 degrees.
Abs Speed (29) Scaled value (absolute) of actual motor speed, range is 0-Max Motor Speed P2003.
Velocity (30) Scaled value (signed) of actual motor speed, range is - Max Motor Speed to +Max
Motor Speed P2003.
Network (31) Represents the network speed reference, see MN744. Analog 1 holding register is
40014:40013, Analog 2 holding register is 40016:40015.
Composite Ref (32) Scaled value of the Composite Reference output, range is -100% to 100% of
composite reference calculation.
Power (kW) (33) Scaling power calculated using nominal output amps and RMS output volts.
Calibrate (34) Produces maximum value of selected analog output type.
ANA OUT1 GAIN
(1512)
ANA OUT2 GAIN
(1515)
Preset Value: 100.0
Preset Value: 100.0
Range: 0.0 - 500.0%
Scale factor for analog output (as in Y=Gain*X)
CAL ANA OUT
(1516)
Preset Value: 0.0
Range: -100.0% to 100.0%
Scalable output signal used to calibrate output device (-100% to 100% of Analog
Out 1 Type).
AT POS BAND
(1517)
Preset Value: 0
Range: 1 to 4095 Counts
The drive at position target if (|Position-Feedback|) < Band.
1551 - 1562
Parameters 1551 - 1562
are used to configure the High Resolution Analog I/O
Expansion Board. See manual MN754 for configuration details.
MOTOR
CONTROL
CONTROL TYPE
(1601)
Preset Value: 2
Range: 0 - 2
V/F Control (0) Sets the control type to V/F Control.
Open Vector (1) Sets the control type to Open Vector.
Closed Vector (2) Sets the control type to Closed Vector.
When changed from Closed to Open Vector, the Level 2, Motor Control, Speed
Int, Speed Diff and Speed Prop gains may need to be reduced (since Open Vector
performance bandwidths are less than for Closed Vector).
Table 7-1 Level 1 Parameter Block Definitions Continued
Содержание VS1GV21-1B
Страница 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Страница 12: ...2 2 General Information MN765...
Страница 16: ...3 4 Installing the Drive MN765...
Страница 78: ...6 16 Using the Keypad MN765...
Страница 132: ...9 14 Troubleshooting MN765...
Страница 169: ...Technical Specifications A 13 MN765 OM2000A11 Size B NEMA 4X Figure A 2 Drive Dimensions and Weights Continued...
Страница 172: ...A 16 Technical Specifications MN765...
Страница 200: ...E 2 Remote Keypad Mounting Template MN765...
Страница 201: ...Remote Keypad Mounting Template E 3 MN765...
Страница 202: ...E 4 Remote Keypad Mounting Template MN765...