B-12 Parameter Tables
MN765
Block Title
Parameter
P#
Adjustable Range
Factory
User Setting
BRAKE
ADJUST
(Continued)
BRAKE ON REVERSE
[2]
2507
0-Off
1-On
0
STOP BRAKE TIME
[2]
2508
0.0 - 60.0 seconds
0.0
BRAKE ON START
[2]
2509
0-Off
1-On
0
START BRAKE TIME
[2]
2510
0.0 - 60.0 seconds
0.0
PROCESS
CONTROL
PROCESS TYPE
2601
0-None
1-Forward Acting
2-Reverse Acting
0
SETPOINT ADJ LIM
2602
0.0 - 100.0%
10.0
PROC FEEDBACK
2603
0-None
1-Setpoint Cmd
2-Local Speed Ref
3-Analog In1
4-Analog In2
5-Network
6-Composite Ref
7-Opt1 Ana In1
8-Opt1 Ana In2
9-Opt2 Ana In1
10-Opt2 Ana In2
0
SETPOINT SOURCE
2604
0
SETPOINT COMMAND
2605
-100.0% to +100.0%
0.0
PROC ERR TOL
2606
0.0 - 100.0%
10.0
PROC PROP GAIN
2607
0.0000 - 9999.9990
1.0000
PROC INTG GAIN
2608
0.0000 - 9999.9990
0.0000
PROC INTG CLAMP
2609
0.0 - 100.0%
100.0
PROC DIFF GAIN
2610
0.0000 - 9999.9990
0.0000
PROFILE ADJUST
2611
0-Off
1-On
0
PROFILE ADJ BAND
2612
0.0 - 200.0%
50.0
PROC SLEEP BAND
2613
0.0 - 100.0%
0.0
PROC OUT FILTER
2614
0.0 - 100.0 seconds
0.00
PROC OUT OFFSET
2615
-100.0 to +100.0%
0.0
PROC OUT GAIN
2616
0.0 - 200.0%
100.0
SKIP FRE-
QUENCY
SKIP FREQ 1
2701
0 - MAX Speed
0.00
SKIP BAND 1
2702
0 - MAX Speed
0.00
SKIP FREQ 2
2703
0 - MAX Speed
0.00
SKIP BAND 2
2704
0 - MAX Speed
0.00
SKIP FREQ 3
2705
0 - MAX Speed
0.00
SKIP BAND 3
2706
0 - MAX Speed
0.00
SYNCHRO
START
SYNC START FWD
[6]
2801
0-Off
1-On
0
SYNC START REV
[6]
2802
0-Off
1-On
0
SYNC AT MAX FREQ
[6]
2803
0-Off
1-On
1
[2]
Only available or active in V/F mode. Ignore thse parameters for Closed/Open Vector mode.
[6]
Only available or active in V/F or Open Vector modes. Ignore for Closed Vector mode. Factory settings are different
depending on mode (V/F or Open Vector).
Note: In Open Vector mode, it is recommended that these values remain at the factory settings.
Table B-2 Parameter Block Values Level 2 (Cont.)
Содержание VS1GV21-1B
Страница 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Страница 12: ...2 2 General Information MN765...
Страница 16: ...3 4 Installing the Drive MN765...
Страница 78: ...6 16 Using the Keypad MN765...
Страница 132: ...9 14 Troubleshooting MN765...
Страница 169: ...Technical Specifications A 13 MN765 OM2000A11 Size B NEMA 4X Figure A 2 Drive Dimensions and Weights Continued...
Страница 172: ...A 16 Technical Specifications MN765...
Страница 200: ...E 2 Remote Keypad Mounting Template MN765...
Страница 201: ...Remote Keypad Mounting Template E 3 MN765...
Страница 202: ...E 4 Remote Keypad Mounting Template MN765...