9-10 Troubleshooting
MN765
Keypad Text
Type
Fault
Number
Description
Memory
Fault
49
Option card problem, memory failure, contact Baldor for service.
Motor Overload
Fault
23
Motor thermal connection at TH1-TH2 open circuit. Motor overheated due to
excess load; Ohm connections at TH1-TH2.
Motor Overload
Fault
80
Motor overloaded. Check motor load. Verify motor rated amps parameter.
Motor Ovrtmp
Alarm
61
Motor has overheated. Check motor cooling system or blocked air flow; check
thermal switch on TH1-TH2 circuit; reduce load on motor.
Network Timeout
Fault
48
Forced network fault. Loss of network communications; watchdog timer
expired; user program timing problems.
New Base ID
Fault
5
Control board detected new or a different power base. Press RESET to
clear. Factory settings will be restored. Verify all settings and setup custom
parameters.
No Fault
Fault
0
No Fault Exists.
NV memory Fail
Fault
30
Problem writing a parameter to the control board EEPROM, contact Baldor for
service.
Opt1 Protocol
Alarm
77
Invalid protocol selected for optional communication card 1. Select a protocol
supported by the expansion board that is installed or replace board with a
board that supports the desired protocol.
Opt2 Protocol
Alarm
78
Invalid protocol selected for optional communication card 2. Select a protocol
supported by the expansion board that is installed or replace board with a
board that supports the desired protocol.
Option Board
Fault
50
Option board not recognized or is not supported. Verify proper firmware version
is being used. Download latest firmware from www.baldor.com and install in
drive.
Option Not Found
Alarm
74
Option Board for the feature requested is not installed. Verify slot location for
expansion board to support desired feature; install appropriate option board for
requested feature.
Over Current
Fault
6
Motor current exceeded peak limit. Check motor connections and motor load;
increase acc/dec times; verify correct motor data settings; verify proper tuning.
Over Speed
Fault
59
Rotor speed over 110% maximum speed limit. Verify proper drive tuning; ensure
drive is not being overhauled by excessive high-speed regenerative load.
Overload - 1 Min
Fault
16
Motor current exceeded 150% for 1 minute. Check motor load. Extend acc/dec
times. Verify proper motor data and drive tuning.
Overload - 3 Sec
Fault
17
Motor current exceeded 175% for 3 seconds. Check motor load and resize
motor and drive as needed. Extend acc/dec times. Verify proper motor data and
drive tuning. Change setting of "Overload" parameter (P2206) to "Foldback" to
allow current to automatically limit to a lower level prior to the 3 second time
limit.
Param Checksum
Fault
4
Cycle power. If no change, load Factory Settings.
Parameter
Fault
55
Parameters momentarily locked. Wait 30 seconds, try again.
PB Power Supply
Alarm
68
Power Base Logic Power Supply below acceptable operating levels.
PCB Over Temp
Alarm
96
Powerbase signal interface PCB board is over heating, reduce loading or
contact Baldor for service.
PF Setup
Alarm
73
Pulse Follower Option Board Setup. Check Master PPR, Receive, Transmit
Ratio and Input Type.
Ph1 (L1) Loss
Alarm
109
Loss of phase 1 (L1), check power grid or wiring connections.
Ph1 Pulse
Fault
45
Phase 1 current limiting via pulse by pulse method; check motor spiking loads,
chattering contacts, loose connections.
Ph2 (L2) Loss
Alarm
110
Loss of phase 2 (L2), check power grid or wiring connections.
Ph2 Pulse
Fault
46
Phase 2 current limiting via pulse by pulse method; check motor spiking loads,
chattering contacts, loose connections.
Ph3 (L3) Loss
Alarm
111
Loss of phase 3 (L3), check power grid or wiring connections.
Ph3 Pulse
Fault
47
Phase 3 current limiting via pulse by pulse method; check motor spiking loads,
chattering contacts, loose connections.
Table 9-1
Fault Messages
Continued
Содержание VS1GV21-1B
Страница 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Страница 12: ...2 2 General Information MN765...
Страница 16: ...3 4 Installing the Drive MN765...
Страница 78: ...6 16 Using the Keypad MN765...
Страница 132: ...9 14 Troubleshooting MN765...
Страница 169: ...Technical Specifications A 13 MN765 OM2000A11 Size B NEMA 4X Figure A 2 Drive Dimensions and Weights Continued...
Страница 172: ...A 16 Technical Specifications MN765...
Страница 200: ...E 2 Remote Keypad Mounting Template MN765...
Страница 201: ...Remote Keypad Mounting Template E 3 MN765...
Страница 202: ...E 4 Remote Keypad Mounting Template MN765...