Parameter Descriptions 7-3
MN765
Block Title Parameter (Number)
Selection (Value)
Parameter Name and Description
KEYPAD
SETUP
STOP KEY
(1301)
Preset Value: 1
Range: 0 - 1
Off (0) Keypad STOP key is not active.
On (1)
Allows keypad STOP key to initiate motor stop during remote or serial operation. If
active, pressing STOP selects Local mode and initiates the stop command. Note:
Pressing STOP key twice in rapid succession will immediately terminate PWM to
motor and disable the drive.
STOP MODE
(1302)
Preset Value: 0
Range: 0 - 1
Regen (0) The voltage and frequency to the motor is reduced at a rate set by Decel Time.
Coast (1) Motor is turned off and allowed to coast to a stop.
Selects if the Stop command causes the motor to COAST to a stop or REGEN to a
stop.
RUN FORWARD
(1303)
Preset Value: 1
Range: 0 - 1
Off (0) Disables FWD key in Local mode.
On (1) Makes the keypad FWD key active in Local mode.
RUN REVERSE
(1304)
Preset Value: 1
Range: 0 - 1
Off (0) Disables REV key in Local mode.
On (1) Makes the keypad REV key active in Local mode.
SWITCH ON FLY
(1305)
(LOCAL/REMOTE KEY)
Preset Value: 0
Range: 0 - 1
Off (0) Disables Switch on Fly.
On (1) Allows switching between Local and Remote while Control is on.
LOCAL HOT START
(1306)
Preset Value: 0
Range: 0 - 1
Off (0) Disables the Stop input at J2-11 in the keypad operating mode.
On (1) Enables the Stop input at J2-11 in the keypad operating mode.
SPEED INCREMENT
(1307)
Preset Value: 30
Range: 1 to 1800 RPM or 0.01 to 60 Hz
Sets the increment of speed change for each key press. (1-3600 RPM or 0-60 Hz)
INIT LOCAL SPEED
(1308)
Preset Value: 0
Range: 0 - 2
Zero Speed (0) Initializes local speed to 0 RPM on Power Up.
Last Speed (1) Initializes local speed to last speed on Power Up.
Set Speed (2) Initializes local speed to “Set Speed” (P1309) on Power Up.
SET SPEED
(1309)
Preset Value: 30
Range: 0 - MAX Speed RPM
At power up, initializes the local speed to this preset value if “Init Local Speed” =
Set Speed.
PARAMS TO KEYPAD
(1310)
Preset Value: 0
Range: 0 - 1
Off (0) No action.
On (1) Transfers the parameter settings stored in the control memory (flash) to keypad
memory.
Table 7-1 Level 1 Parameter Block Definitions Continued
Содержание VS1GV21-1B
Страница 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Страница 12: ...2 2 General Information MN765...
Страница 16: ...3 4 Installing the Drive MN765...
Страница 78: ...6 16 Using the Keypad MN765...
Страница 132: ...9 14 Troubleshooting MN765...
Страница 169: ...Technical Specifications A 13 MN765 OM2000A11 Size B NEMA 4X Figure A 2 Drive Dimensions and Weights Continued...
Страница 172: ...A 16 Technical Specifications MN765...
Страница 200: ...E 2 Remote Keypad Mounting Template MN765...
Страница 201: ...Remote Keypad Mounting Template E 3 MN765...
Страница 202: ...E 4 Remote Keypad Mounting Template MN765...