6-9
Chapter 6. Communication Data
(4) Add a decimal point according to the totalized flow rate digits after the
decimal point (communication) setting: 80877102
→
808771.02
(5) Add the unit: 808771.02
→
808771.02 L
When writing total flow volume–related data, use the reverse procedure and write
the separate values.
Data related to function settings
Note
•
Digital Mass Flow Controller Model F4Q User's Manual
, CP-SP-1461E (for
details of the functions)
Item
Data range
/ [unit]
Data address
Decimal
(hexadecimal)
R
W
Notes
(C-01)
Key lock
0: Key lock disabled
1: Settings other than
flow rate (SP) and
RUN are key-locked
2: All settings are key-
locked
2001 (07D1)
✓
✓
(C-02)
Operational mode
selection when power
turned ON
0: Control mode
1: Mode before power
shutdown
2: Fully closed mode
2002 (07D2)
✓
✓
(C-03)
Flow rate setup method
(SP setup method
selection)
0: Select from SP-0 to
SP-7
1: Analog setup
2: Online SP
2003 (07D3)
✓
✓
(C-04)
Undefined
Always 0
2004 (07D4)
–
–
Returns “0” when the setting is read
and returns a normal response when
written.
(C-05)
Undefined
Always 0
2005 (07D5)
–
–
Returns “0” when the setting is read
and returns a normal response when
written.
(C-06)
Analog input and
output type and range
selection
0: 0 to 5 V (PV output)
1: 1 to 5 V (PV output)
3: 4 to 20 mA (PV output)
4: 0 to 5 V (SP output)
5: 1 to 5 V (SP output)
7: 4 to 20 mA (SP output)
2006 (07D6)
✓
✓
Содержание F4Q
Страница 10: ......
Страница 14: ......
Страница 46: ......
Страница 66: ...7 2 Chapter 7 Device Operation by Communication Commands...
Страница 68: ......
Страница 70: ......
Страница 71: ...Revision History CP SP 1458E Printed Edn New Page No Description June 2021 1...
Страница 72: ......
Страница 73: ......