2-2
Chapter 2. Wiring
2 - 2
Terminal Layout of This Device
The terminal layout of this device is shown below.
Terminal
No. 20
Terminal
No. 11
Terminal
No. 10
Terminal
No. 1
z
Connector signal table
Terminal
No.
Signal
Description
Notes
1
DA
RS-485 comm., DA
2
DB
RS-485 comm., DB
3
S.GND
RS-485 comm. (−)
4
AI
Analog input (+)
Flow rate set point (SP) input
5
AO
Analog output (+)
Controlled flow rate (PV) or flow rate set point (SP)
output
6
A.GND
Analog signal (−)
Common ground for analog signals
7
P.GND
24 V DC (−) power
8
P.GND
24 V DC (−) power
9
POWER (24 V)
24 V DC (+) power
10
POWER (24 V)
24 V DC (+) power
11
DO1
Digital output 1 (+)
Open drain non-isolated output
12
DO2
Digital output 2 (+)
13
DO3
Digital output 3 (+)
14
D.GND
Digital signal (−)
Common ground for digital signals
15
DI1
Digital input 1 (+)
2-way (OPEN/GND) switching input
16
DI2
Digital input 2 (+)
17
DI3
Digital input 3 (+)
18
D.GND
Digital signal (−)
Common ground for digital signals
19
-
Not connected
20
-
Not connected
Note
•
For wiring not related to the RS-485 communication line:
Digital Mass Flow Controller Model F4Q User’s Manual
, CP-SP-1461E.
Содержание F4Q
Страница 10: ......
Страница 14: ......
Страница 46: ......
Страница 66: ...7 2 Chapter 7 Device Operation by Communication Commands...
Страница 68: ......
Страница 70: ......
Страница 71: ...Revision History CP SP 1458E Printed Edn New Page No Description June 2021 1...
Страница 72: ......
Страница 73: ......