![Avery Dennison Monarch Tabletop Printer 2 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/avery-dennison/monarch-tabletop-printer-2/monarch-tabletop-printer-2_reference-manual_3030512069.webp)
Classification: Avery Dennison – Public
Defining Fields
3-21
B12. field rot
Field rotation. Field rotation rotates the whole field, not jus t the
c harac ters . Rotation is affec ted by the pivot point, whic h varies
depending on how text is jus tified. Lower left c orner of field is
the pivot point.
0
is the default. Options :
0
Top of field points to top of s upply (us e for MaxiCode)
1
Top of field points to left of s upply
2
Top of field points to bottom of s upply
3
Top of field points to right of s upply
Note :
Serial bar c odes with an 8-dot narrow elem ent do not
autom atic ally print at 2.5 IPS. Serial bar c odes printed at s peeds
greater than 2.5 IPS m ay not s c an properly.
B13. ty pe
Selec t from the bar c ode fam ily.
This param eter only applies to
the GS1 DataBar bar c ode. 1
is the default.
For other bar
c odes , do not inc lude this param eter. Options :
1
GS1 DataBar 14
2
GS1 DataBar 14 Trunc ated
3
GS1 DataBar 14 Stac ked
4
GS1 DataBar 14 Stac ked Om ni direc tional
5
GS1 DataBar Lim ited
6
GS1 DataBar Expanded
7
UPCA
8
UPCE
9
EAN13
10
EAN8
11
UCC/EAN128 and CC A/B
12
UCC/EAN128 and CC C
B14. s ep_height
Height of the s eparator between the linear bar c ode and 2D bar
c ode.
This param eter only applies to the GS1 DataBar bar c ode.
For other bar c odes , do not inc lude this param eter. The value is
1
or
2
.
1
is the default.
B15. s egm ent
W idth of the s egm ent.
This param eter only applies to the GS1
DataBar bar c ode.
For other bar c odes , do not inc lude this
param eter.
The range is even num bers from
2
to
22
.
22
is the
default.
Exam ple
B ,3 ,1 2,V,50 ,4 0,1,2,80,7,L,0 |
Defines a bar c ode field (field #3) with 12 c harac ters of variable length s tarting at row 150,
c olum n 40. A UPCA bar c ode with a dens ity of 2 and a height of 80 is us ed. The c hec k digit and
num ber s ys tem are s hown at the bottom . The bar c ode is left aligned without any field rotation.
Содержание Monarch Tabletop Printer 2
Страница 10: ...viii Packet Reference Manual Classification Avery Dennison Public...
Страница 16: ...1 6 Packet Reference Manual Classification Avery Dennison Public...
Страница 48: ...2 32 Packet Reference Manual Classification Avery Dennison Public...
Страница 80: ...3 32 Packet Reference Manual Classification Avery Dennison Public...
Страница 102: ...4 22 Packet Reference Manual Classification Avery Dennison Public...
Страница 138: ...7 10 Packet Reference Manual Classification Avery Dennison Public...
Страница 156: ...8 18 Packet Reference Manual Classification Avery Dennison Public...
Страница 160: ...9 4 Packet Reference Manual Classification Avery Dennison Public...
Страница 196: ...C 8 Packet Reference Manual Classification Avery Dennison Public...
Страница 198: ...D 2 Packet Reference Manual Classification Avery Dennison Public O n lin e Co n figur ation W o r k sheet...
Страница 199: ...Classification Avery Dennison Public Format Design Tools D 3 Su p p ly L a y out G r id s En g lis h...
Страница 200: ...D 4 Packet Reference Manual Classification Avery Dennison Public Su p p ly L a y out G r id s M e tr ic...
Страница 201: ...Classification Avery Dennison Public Format Design Tools D 5 Su p p ly L a y out G r id s Do ts...
Страница 202: ...D 6 Packet Reference Manual Classification Avery Dennison Public...
Страница 205: ......