ACD contact center features
186 Communication Manager Guide to ACD Call Centers
Supplementary Service Protocol: Telcordia-TBCT
Network Call Redirection: NCT
For NCD, the
Supplementary Service Protocol
field must be set to c and the
Network Call Redirection
field must be set to deflect. Refer to the following
screens:
change trunk-group 29 Page 1 of 23
TRUNK GROUP
Group Number: 29 Group Type: isdn CDR Reports: y
Group Name: 5ESS-1 COR: 1 TN: 1 TAC: 729
Direction: two-way Outgoing Display? y
Dial Access? n Busy Threshold: 255 Night Service:
Queue Length: 0
Service Type: sdn Auth Code? n TestCall ITC: rest
Far End Test Line No:
TestCall BCC: 4
TRUNK PARAMETERS
Codeset to Send Display: 7 Codeset to Send National IEs: 7
Max Message Size to Send: 260 Charge Advice: none
Supplementary Service Protocol: a Digit Handling (in/out): enbloc/enbloc
Trunk Hunt: descend
Digital Loss Group: 13
Calling Number - Delete: Insert: Numbering Format:
Bit Rate: 1200 Synchronization: async Duplex: full
Disconnect Supervision - In? y Out? y
Answer Supervision Timeout: 0
change trunk-group 29 Page 2 of 23
TRUNK FEATURES
ACA Assignment? n Measured: both Wideband Support? n
Maintenance Tests? y
Data Restriction? n NCA-TSC Trunk Member:
Send Name: n Send Calling Number: n
Used for DCS? n
Suppress # Outpulsing? n
Outgoing Channel ID Encoding: preferred UUI IE Treatment: shared
Maximum Size of UUI IE Contents: 128
Replace Restricted Numbers? n
Replace Unavailable Numbers? n
Send Connected Number: n
Network Call Redirection: Nortel-transfer
Send UCID? y BSR Reply-best DISC Cause Value: 31
Send Codeset 6/7 LAI IE? n
Network (Japan) Needs Connect Before Disconnect? N
Содержание Communication Manager Contact Center
Страница 4: ......
Страница 52: ...Automatic Call Distribution ACD basics 52 Communication Manager Guide to ACD Call Centers...
Страница 280: ...ACD contact center features 280 Communication Manager Guide to ACD Call Centers...
Страница 434: ...ZCS 434 Communication Manager Guide to ACD Call Centers...