Call Management System (Category A only)
Issue 1.0 May 2003
121
Determining allocation of measured trunks and unmeasured facilities
Maximum values for measured trunks and unmeasured trunk facilities are specified for
each ACD in the CMS Data Storage Allocation window. For CMS release R3V11, the
total capacity for measured trunks and unmeasured facilities across all ACDs is 40000.
The recommended assignment of unmeasured facilities per ACD is 25% of the total
number of trunks that are allocated for the ACD. However, the number of unmeasured
trunk facilities that you choose to allocate for a particular ACD may vary according to the
nature of your contact center operations.
Considerations for administering the communication server-
to-CMS interface
You must consider the following factors when administering the communication server-to-
CMS interface.
CMS measurements
CMS measurements may be inaccurate on calls to splits that intraflow to the attendant
group.
IP Trunk Groups and ATM Trunk Groups
External IP trunk number identifier (Port ID) information is sent from the communication
server to the CMS. Two types of messages can send information about single trunk group
members and about status changes (from measured to unmeasured, or from unmeasured
to measured via CMS) of trunk group members.
When IP trunk groups are administered on the communication server, the cabinet location
of the associated C-LAN board is determined for each IP trunk group member. When
message information is reported to the CMS, the location-id is copied into the message. as
a number in the range of 1 through 400 in the circuit field of the messages sent to CMS.
For example, an IP trunk member with a port-id of T00001 is displayed on CMS as
00000001, and an IP trunk member with port-id of T00400 will be displayed on CMS as
0000400.
CMS representation of IP trunk member port-ids
To display IP trunk member port-ids to the CMS, the circuit field accommodates a number
in the range from 1 to 511. To report an IP trunk member number in the range of 1 to 5000
requires the use of both the slot field in the message and the circuit field.
Содержание Communication Manager Contact Center
Страница 4: ......
Страница 52: ...Automatic Call Distribution ACD basics 52 Communication Manager Guide to ACD Call Centers...
Страница 280: ...ACD contact center features 280 Communication Manager Guide to ACD Call Centers...