Best Service Routing (Category A only)
Issue 1.0 May 2003
103
An example signaling-group form configured for BSR polling over IP without B-channel is
shown below.
Trunk Group form
Use the
display trunk-group xx
command (where
xx
is the signaling group number)
to display the Trunk Group form. Verify that your administration settings comply with the
requirements listed below each of the following example form pages.
Examples for the key pages in the Pattern form that must be configured for BSR polling
over IP without B-channel are shown below.
display signaling-group 32
SIGNALING GROUP
Group Number: 32 Group Type: h.323
Remote Office? n Max number of NCA TSC: 10
Max number of CA TSC: 10
Trunk Group for NCA TSC: 32
Trunk Group for Channel Selection: 32
Supplementary Service Protocol: b Network Call Transfer? n
Near-end Node Name: clan-01D12 Far-end Node Name: cland12-loop
Near-end Listen Port: 1720 Far-end Listen Port: 1720
Far-end Network Region:
LRQ Required? n Calls Share IP Signaling Connection?y
RRQ Required? n
Bypass If IP Threshold Exceeded?n
Direct IP-IP Audio Connections?y
IP Audio Hairpinning?y
Interworking Message: PROGress