Configuring Communication
41
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
NOTE:
The Network Interface Select field is read-only and defaulted to Wireless, since the device has no Ethernet cable
connection.
7.
Press the
Web Control Name
field to open the
Web Name
keyboard.
8.
From the
Web Name
keyboard, enter a unique alpha-numeric string to identify this panel.
This information is used by the NetLinx Security Web Server to display on-screen links to the panel.
The on-screen links use the IP Address of the panel and not the name for communication (FIG. 43).
9.
Assign the alpha-numeric string for the Web Control name and then press
Done
.
10. Press the
Web Control Password
field to open the
Web Password
keyboard.
11. From the
Web Password
keyboard, enter a unique alpha-numeric string to be assigned as the G4 Authentication session
password associated with VNC web access of this panel.
12. Press
Done
after assigning the alpha-numeric string for the Web Control password.
13. Press the
Web Control Port
field to open the
Web Port Number
keypad.
14. Within the keypad, enter a unique numeric value to be assigned to the port on which the VNC Web Server is running. The
default value is
5900
. Press
Done
after entering the value. The remaining fields within the
G4 Web Control Settings
section of
this page are read-only and cannot be altered.
15. Press the
Up/Down
arrows on either sides of the
G4 Web Control Timeout
field to increase or decrease the amount of time the
device can remain idle
with no cursor movements
before the session is closed and the user is disconnected.
16. Press the
Back
button to open the
Protected Setup
page.
17. Press the on-screen
Reboot
button to save any changes and restart the device.
NOTE:
Verify that the NetLinx Master’s IP Address and System Number have been properly entered into the
Master Connection
section of the
System Settings
page.
Using the NetLinx Master To Control the G4 Panel
Refer to the particular NetLinx Master’s instruction manual for detailed information on how to download the latest firmware from
www.amx.com
. This firmware build enables SSL certificate identification and encryption, HTTPS communication, ICSP data
encryption, and disables the ability to alter the Master security properties via a TELNET session.
NOTE:
In order to make full use of the SSL encryption, the web browser used should incorporate an encryption feature. This
encryption level is displayed as a Cipher strength.
Once the Master’s IP Address has been set through NetLinx Studio version 2.x or higher:
1.
Launch your web browser.
2.
Enter the IP Address of the target Master (
example: http://198.198.99.99
) into the web browser’s
Address
field.
3.
Press the
Enter
key on your keyboard to begin the communication process between the target Master and your computer.
Initially, the
Master Security
option is disabled from within the
System Security
page, and no username and password is
required for access or configuration.
Both HTTP and HTTPS Ports are enabled by default via the
Manage System
>
Server
page.
If the Master has been previously configured for secured communication, click
OK
to accept the AMX SSL certificate,
if SSL
is enabled
, and then enter a valid username and password into the fields within the
Login
dialog.
4.
Click
OK
to enter the information and proceed to the Master’s
Manage WebControl Connections
window. This page (FIG. 44) is
accessed by clicking on the
Manage connections
link (
within the Web Control section within the Navigation frame
). Once
activated, this page displays links to G4 panels running the latest G4 Web Control feature that were previously set up and
activated on the device.
FIG. 43
Sample relationship between G4 Web Control and Mange WebControl Connections window