Accessories
22
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
Unlocking the Touch Panel
Once placed within the Wall Charging Station, the MVP-5200i remains secured until the user unlocks it. A ten-second lag between
the touch panel being placed in the Wall Charging Station and the security feature enabling allows the user to remove the touch
panel if it is accidentally put into the device. To release the touch panel from the Wall Charging Station:
1.
Press the Security Release button (see FIG. 9).
2.
A password keypad will pop up on the MVP-5200i screen. Enter a password in the password keypad and press
Enter
.
3.
Wait for the Wall Charging Station to pivot the touch panel away from the wall.
4.
The device will remain in the ejected position until the MVP-5200i is removed. Wait until the device’s ejection door has
completely withdrawn before re-installing the MVP-5200i.
NOTE:
Unique passwords may be entered for up to four unique users as well as the administrator. For more information on setting
passwords, please refer to the Password Settings Page
section on page 67
.
Recharging
To recharge the MVP-5200i:
1.
Slide the device into the Wall Charging Station cradle bottom-first and make sure the device is fully seated in the Charging
Station.
2.
Press the top of the MVP-5200i back until it clicks. The touch panel is now locked into the Charging Station, and the station
will automatically charge the device’s battery. (Please refer to the
Power Management Page
section on page 50 to check on
the battery charge status.)
3.
To release the touch panel, unlock the touch panel and wait for the Wall Charging Station to pivot the touch panel away from
the wall.
Installing the MVP-WCS-52
Since the Wall Charging Station is intended to be affixed to a wall or other permanent structure, care must be taken to ensure its
proper installation to prevent potential damage to the MVP-5200i placed within.
NOTE:
Other than wall installation tools, the only tool required for this installation is a #1 Phillips screwdriver.
Installing the Plastic Back Box
The plastic Back Box has two knockouts at the top of the box and four (4) lockdown wings attached to the box with Phillips-head
screws. For ease of installation, the interior of the box contains an "UP" arrow pointing to the knockouts. The Metal Rough-In Box
does not have to be installed beforehand, but it offers an extra level of support.
To install the Plastic Back Box:
1.
Cut a hole into the wall or surface intended to hold the box. The outer lip of the box is sized 8.69 inches (220.66mm) long and
6.0 inches (152.4mm) high, so the hole should be at least 1/4" (6.4mm) smaller in each dimension (FIG. 10). Use the included
MVP-WCS-52 Wall Charging Station Template (
68-5966-01
) as an aid for hole placement and measurement.
FIG. 10
Recommended cutout for plastic back box
8.25"
(209.55mm)
5.56"
(141.29mm)
8.25"
(209.55mm)
5.56"
(141.29mm)