Configuring Communication
40
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
By selecting
URL
, the
System Number
field becomes read-only (grey) because the panel pulls this value directly from the
communicating target Master, virtual or not. A Virtual Master system value can be set within the active AMX software
applications such as NetLinx Studio, TPD4, or IREdit.
15. Press the
Master IP/URL
field to open a Keyboard and enter the IP Address of the PC used as the Virtual Master.
16. Click
Done
to accept the new value and return to the
System Settings
page.
17. Do not alter the
Master Port Number
value, as this is the default value used by NetLinx.
18. Press the
Back
button to return to the
Protected Setup
page, and
Exit
to return to the
Setup
page.
19. The USB connection will be signified by the
WiFi/Wired/USB
icon changing into a
USB
icon (FIG. 41).
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4-enabled panel via the Web. This feature works in tandem
with the new browser-capable NetLinx Security firmware update (
build 300 or higher
). G4 Web Control is only available with the
latest Modero panel firmware.
Refer to the
G4 Web Control Settings Page
section on page 65 for more detailed field information.
NOTE:
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest firmware KIT file from www.amx.com.
Refer to the NetLinx Master instruction manual for more detailed information on the use of the new Web-based NetLinx Security.
1.
Press and hold the two lower buttons on both sides of the display for
3 seconds
to open the
Setup
page.
2.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the
Protected Setup
page and display
an on-screen keypad.
3.
Enter the appropriate password into the Keypad’s password field (
the default password is 1988
) and press
Done
.
4.
Press the
G4 WebControl
button to open the
G4 Web Control Settings
page (FIG. 42).
5.
Press the
Enable/Enabled
button until it toggles to
Enabled
and turns light blue.
6.
The
Network Interface Select
field is read-only and displays the method of communication to the web.
Wireless
is used when a wireless card is detected within the internal card slot. This method provides an indirect
communication to the web via a pre-configured Access Point.
FIG. 41
USB icon
FIG. 42
G4 Web Control page