3-2 | Thermox Series 2000 WDG-HPII / HPIIC - ATEX
Mechanical Installation
This section describes how to perform the mechanical installation portion
of your system installation. This includes the following:
•
Probe and Probe Filter Connection to Sensor
•
Sensor Mounting
•
Remote Calibration Unit Mechanical Installation (optional)
Observe the following guidelines when selecting an analyzer instal-
lation location:
1. Select a readily accessible position for the analyzer to allow for
routine maintenance. Comfort levels for maintenance person-
nel should be considered in placement of the sensor and con-
trols interface.
2. The installation location should be free from excessive vibration
and the ambient temperature is required to be within the limits
listed in the specifications appendix contained in this manual.
If the ambient temperature is outside the specified limits or the
vibration is excessive, please contact Thermox Sales or Service
Department at 412.828.9040. Special options exist to address
ambient temperatures outside the listed specifications and spe-
cial-mounting solutions can be provided for excessive vibration
installation locations.
Probe and Probe Filter Connection to Sensor
The sample probe must be attached to the back of the sensor before mount-
ing the sensor to the process.
Do not use pipe dope or any other contaminant on any joints of the
sample tubing that give off combustible vapor. Teflon tape is permis-
sible if the joint temperature will not exceed 200
o
C.
!
CAUTION
!
CAUTION
Содержание Thermox 2000 ATEX Series
Страница 18: ...1 8 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...
Страница 24: ...2 6 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...
Страница 68: ...3 44 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...
Страница 128: ...5 28 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...
Страница 149: ...Service and Parts 7 3 Figure 7 1 Wiring diagram for standard sensor...
Страница 151: ...Service and Parts 7 5 Figure 7 2 Cell replacement...
Страница 153: ...Service and Parts 7 7 Figure 7 3 Furnace thermocouple replacement...
Страница 157: ...Service and Parts 7 11 Figure 7 5 Furnace replacement...
Страница 159: ...Service and Parts 7 13 Figure 7 6 Combustibles detector replacement Hot Wire...
Страница 196: ...B 4 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...
Страница 202: ...D 2 Thermox Series 2000 WDG HPII HPIIC ATEX This page intentionally left blank...