Use of the implement
168
UX01 Super CP Plus BAG0229.2 11.21
11.2.6 Filling the flushing water tank
Suction filling for implements without flushing water pump:
WARNING
Damage to crops and soils.
Suction filling of the flushing water tank in case of contamination of
the valve chest with critical agents:
•
Clean the implement thoroughly beforehand.
•
Suction filling is forbidden if contamination of the flushing water
tank with critical agents is to be expected.
Suction filling for implements without flushing water pump:
To avoid contamination of the flushing water tank with spray agent
residues, the spray liquid tank must first be filled with 600 l of water
before the flushing water tank (flushing of the valve chest).
TwinTerminal:
It is preferable to fill the flushing water tank while
you are filling the spray liquid tank.
Suction filling without the flushing water
pump
1. Drive the pump (at least 400 rpm).
2. Enter the target fill level for the spray liquid
tank (at least + 500 l).
3. Enter the target fill level for the flushing
water tank.
4.
Start filling both tanks.
→
(first flushing in the spray liquid tank, then
filling the flushing water tank).
Suction filling with the flushing water pump
1. Enter the target fill level for the flushing
water tank.
2.
Start the filling procedure.
The flushing water pump starts automatically.
Pressure filling
1. Enter the target fill level for the flushing
water tank.
2.
Start the filling procedure.
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......